The degree of avoid ingress of water or particulate matter into ME equipment
Avoid the sun
Handle gently
Temperature range
No Sterilize requirement
Not category AP / APG equipment
Mode of operation: continuous
Memory
At the end of a measurement, this monitor automatically stores each result with
date and time. Each unit stores 120 sets measurements for 2 users (User A
and B).
Viewing the stored values
With the unit off, press the Memory button. The display first shows "A", Then
shows an average of last 3 times measurements stored in the unit. Please
note: Measurements for each user are last 3 times average and stored
separately. Be certain that you are viewing the measurements for the correct
user. Pressing the Memory button again displays the previous value. To view a
particular stored memory, press and hold the Memory button to scroll to that
stored reading.
Discontinuing a Measurement
If it is necessary to interrupt a blood pressure measurement for any reason (e.g
the patient feels unwell), the Start/Stop button can be pressed at any time. The
device then immediately lowers the cuff pressure automatically.
Battery Change Indicator
Batteries discharged-replacements required
When the batteries are discharged, the battery symbol will flash as soon as the
instrument is switched on. You cannot take any further measurements and
must replace the batteries.
The battery compartment is located on the back side of the unit.
A) Remove cover from the bottom plate, as illustrated below picture-08.
B) Insert the batteries (4 x size AAA). Always use AAA long life batteries or
alkaline 1.5v batteries.
C) The memory retains all values although date and time (and possibly also set
alarm times) must be reset - the year number therefore flashes automatically
after the batteries are replaced.
D) To set date and time, follow the procedure described in Section 4.2.
Which batteries and which procedure?
Use four new, long life 1.5v AAA batteries. Do not use batteries beyond their
expiration date. If the monitor is not going to be used for a prolonged period the
batteries should be removed.
Using rechargeable batteries
You can also operate this instrument using rechargeable batteries.
Only use "NiMH" reusable batteries!
If the battery symbol the batteries must be removed and recharged! They must
not remain inside the instrument, as they may become damaged through total
discharge even when switched off. The batteries must not be discharged in the
blood pressure monitor! If you do not intend to use the instrument for a week or
more, always remove the rechargeable batteries!
Recharge these batteries using an external charger and follow manufacturer's
instructions Carefully.

Using the AC Adapter

You may also operate this monitor using the AC adapter (output 5V DC/1 A
with Micro USB plug).