Herunterladen Inhalt Inhalt Diese Seite drucken

Connection To The Voltage Supply; Connection To The Digital System; Connection Of Double-Coil Point Drives - Lenz Digital Plus LS150 Handbuch

Vorschau ausblenden Andere Handbücher für Digital Plus LS150:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

22

Connection to the voltage supply

Please see Figure 1(Page 21), bottom left:
Connect the terminals () with the terminals of the transformer. Observe the
maximum permissible voltage (see Technical data). The power of the transformer
must not exceed 45VA in order to guarantee a functioning load protection. We
recommend the use of the Digital plus by Lenz
26000).
Under no circumstances must the transformers TR150 and TR200
be used!

Connection to the digital system

Please see Figure 1(Page 21), bottom right:
Connect the terminals J,K with the track output of the digital system. In the
Digital plus by Lenz

Connection of double-coil point drives

Please see Figure 1(Page 21), top left:
The common connection of the two coils (2) is connected to terminal 'C'. The
cable of coil 1 (1) is connected to terminal '+'; the cable of coil 2 (3) to terminal '-'.
Depending on the drive used, when the output '+' is activated this results in the
position 'branch' for a point and the position 'stop' for a semaphore signal. If this
is not what you desire, simply swap the connections at the terminals '+' and '-'.
The following table contains the most common colour codings of some
manufacturers, with reference to the numbering of the cables in Abbildung 1.
Please use the operating manual of the drive used to verify whether cable colours
have been changed!
Cable no.:
ROCO
Arnold
Fleischmann
Trix
Märklin
Viessmann semaphore signal
®
system the track output is also marked with J and K.
®
transformer TR100 (art. no.
1
2
red
black
blue
grey
beige
black
yellow
black
blue
yellow
green
brown
3
green
purple
brown
green
blue
red

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

11150