Part 2
To convert the appliance to another type of gas, e.g. from natural gas
to LPG, the nozzles of the main burner, by-pass and pilot light have
to be changed. All the nozzles are marked with a number that
indicates the diameter in 1/100 and are supplied in a bag.
Connections to the distribution network, installation, and maintenance of the appliance must only be carried out by qualified
technicians only, in observance of all applicable regulations!
BURNER:
Open the doors and find the nozzles (fig.5).
Replace the nozzles "U" (fig.5) with suitable ones for the new type of
gas see nozzles table - T1 in the section Specifications.
ADJUSTING THE AIR:
Unscrew the screw holding the primary air adjustment bush. Move
the bush to the distance "H" (fig.7) indicated in the nozzles table T1
in the section Specifications.
Block the bush by tightening its fixing screw.
Replacing the nozzles and adjusting the air
GB / IE - 3
Transformation and adaptation
After each conversion or adaptation, the unit must undergo an
operating test and the supplementary plate must be updated
according to the conversion or adaptation carried out.
PILOT LIGHT:
Unscrew and remove the closing nut.
Replace pilot nozzle "D" (fig.3) on the basis of the indications in the
nozzles table - T1.
Reassemble the closing nut.