Herunterladen Diese Seite drucken

SSS Siedle AGW 671-0 Produktinformation Seite 3

Access-gateway
Vorschau ausblenden Andere Handbücher für AGW 671-0:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

English
Application
Access gateway for the physical
separation of 2 networks at an
Access server. To operate Access end
devices in different networks, two or
more proprietary networks can be
connected to an Access system and
still be kept strictly separate from
each other by using one or more
Access gateways in larger network
structures.
Operation of the AGW 671-...
requires the Access server V. 6.0.1
as a minimum requirement. If appli-
cable, a software upgrade/update
must be carried out.
General information
Commissioning of the Access
gateway is described in the Access
Professional commissioning instruc-
tions and is available in the Siedle
download area.
Electrical voltage
Mounting, installation and servicing
work on electrical devices may only
be performed by a suitably qualified
electrician.
Network configuration (Customer)
Commissioning date:
IP address:
Subnet mask:
Default gateway:
DHCP server activated?
IP pool, start:
IP pool, end:
Serial number:
MAC address:
Location:
Scope of supply
• AGW 671-...
• Power supply unit
• this product information
Mounting
• Connection to the Access network
takes place via the LAN socket
"Access". The IP address is issued by
DHCP. No other settings are required
here.
• Connection to the customer
network takes place via the LAN
socket "Customer". The IP address
is pre-set.
Specifications
Components:
CPU: AMD Geode LX800; 500 MHz
Working memory:
256 MB DDR SDRAM
LAN: 3 x 100 Mbit/s
Operating voltage: 12 V DC
Typical current consumption:
max. 24 W
Ambient temperature:
0 °C to +50 °C
Dimensions (mm) W x H x D:
200 x 200 x 52
Commissioning
• The IP address of the Access server
is required for the complete commis-
sioning of the Access gateway.
• The laptop and Access gateway
must be in the same network.
When accessing via the LAN socket
"Customer", adjust the network
address of the laptop to the IP
address range (192.168.240.x).
Procedure
1 Connect the laptop to the LAN
socket "Customer" of the Access
gateway.
2 Open a browser and enter the IP
address "192.168.240.1".
3 The login window will open up.
4 Enter password "admin".
5 Configure the Access gateway.
3