(1) measurement of air flow
(2) Airborne acoustical noise
To determine the results, and in accordance with the requirements in relation to
the labelling of energy-related products and with regard to ecodesign requirements,
the following calculation and measurement methods were applied:
➢ Directive of the European Parliament and of the Council 2010/30/EU;
REGULATION NO 65/2014.
➢ Directive of the European Parliament and of the Council 2009/125/EC;
REGULATION NO 66/2014.
➢ EN 50564 - Electrical and electronic household and office equipment.
Measurement of low power consumption
➢ EN 60704-2-13 - Household and similar electrical appliances. Test code for the
determination of airborne acoustical noise. Particular requirements for range
hoods.
➢ EN 61591 - Household range hoods and other cooking fume extractors -
Methods for measuring performance.

6.2 Relevant data for installation

Voltage/frequency
Grease filter/material/dishwasher-proof
Carbon filter *
Exhaust hose
Installation material
Exhaust air operation
Air recirculation
Instruction manual
Telescopic chimney extractable from-to
Installation with ventilation stack or air duct
outwards
Dimensions H*W*D in cm
Weight net/gross in kg
*
Optional equipment.
Range hoods with a maximum air flow, which
is more than 650 m
must automatically change to an air flow,
which is max. 650 m
According to dB(A) re 1 pW.
1
Wall penetration = 150 mm Ø
Drilling = approx. 160 mm Ø
38,70-113,70*59,50(89,50)*37,20
10,50/12,50 kg (50cm)
11,00/13,00 kg (60cm)
13,00/15,00 kg (90cm)
47
3
/h at an available setting,
3
/h.
AC 220-240V/50Hz
aluminium
2*CF 140
40.00-75.00 cm