Technical features
Tank capacity
Number of activations
Special function
Available dispensers
Power supply
Heating consumption
Maintenance consumption
Buffer battery
Initial heating time
Heating time after an activation
Operation without 220AC
network
Dimensions in mm (WxHxD)
Weight
Environmental conditions
Temperature and Humidity
Status indicator
Inputs
Outputs
12 volt = output
Connections
Events memory
Check Status and Programming
Firmware update
IMQ
The products must be used according to the intended use and in compliance with the rules applicable
to the various plant engineering types.
However, before commissioning the installed products, the system must be tested in order to verify its
functioning and compliance with the safety rules according to that indicated by Law n. 46 dated 05/03/
90 and by Standard CEI 79-3.
The equipment must not be exposed to dripping or water sprays and no object full of liquid must be
placed on it.
Consider the environmental consequences deriving from the elimination of the batteries
To prevent injury, this device must be secured to the ceiling/wall according to the installation instructions.
INSTALLATION AND MAINTENANCE MUST BE EXECUTED BY QUALIFIED PERSONNEL
FOGGY 30
• 1 litre
30 activations of 10'' each
5 activations of 60'' each
• Management Activation and Deactivation through
remote controls
No. 1: 90° tent with a jet
No. 3 with different angles and deployments (optional)
• 230 V ~
• 700 Watt
• 120 Watt
• Yes
• 12 minutes
• Maximum of 5 minutes
• At least 1 hour with B setting (deployment 20 sec.)
• 358 x 264 x 163
• 14Kg
• environmental class II - inside- general
• from - 10 °C to + 40°C with average humidity of about
75% and not subject to condensation
• Through led and display
System arming: follows alarm system on/off·
Primary Alarm: pre-alarm·
Secondary alarm: alarm; jet activation
Total block
Block due to fire
Deployment in progress
Tampering
Liquid Level
Technical malfunction: No network – Battery level –
Battery fault - Pump malfunctioning - Board temperature
- Boiler temperature
• Yes, maximum current issued 50 mA
Universal standards·
Serial RS485 dedicated to AVS systems
• n° 1000 events can be memorised with date and time
Local USB connection
GSM dial-up (with mod. XGSM optional)
• Yes - by PC
• EN 50131-8 Class II
• 1.5 litre
23 activations of 20'' each
7 activations of 60'' each
• Management Activation and Deactivation through
remote controls
No. 1: 90° tent with a jet
No. 3 with different angles and deployments (optional)
• 230 V ~
• 1100 Watt
• 200 Watt
• Yes
• 20 minutes
• Maximum of 5 minutes
• At least 1 hour with B setting (deployment 20 sec.)
• 480 x 354 x 165
• 22Kg
• environmental class II - inside- general
• from - 10 °C to + 40°C with average humidity of about
75% and not subject to condensation
• Through led and display
System arming: follows alarm system on/off·
Primary Alarm: pre-alarm·
Secondary alarm: alarm; jet activation
Total block
Block due to fire
Deployment in progress
Tampering
Liquid Level
Technical malfunction: No network – Battery level –
Battery fault - Pump malfunctioning - Board temperature
- Boiler temperature
• Yes, maximum current issued 50 mA
Universal standards·
Serial RS485 dedicated to AVS systems
• n° 1000 events can be memorised with date and time
Local USB connection
GSM dial-up (with mod. XGSM optional)
• Yes - by PC
• EN 50131-8 Class II
- 29 -