Herunterladen Inhalt Inhalt Diese Seite drucken

Error Indicators - PCE PRCD-K+ Betriebsanleitung

Personenschutzschalter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Error indicators:

red
are indicated by the signal unit
Differential current faults
RED. In this case, the PRCD-K + from PCE gives a visual
flashing
warning and switches off immediately. The PE conductor circuit
remains closed until the fault is cancelled!
>Push
If, when switching on, the signal unit
illuminates RED or
neutral, there is a fault. The PRCD-K + does not switch
remains
ON. Consult a qualified electrician
.
If there is already an
when plugging in the
under voltage
PRCD-K + unit, the LED unit
(if there is
flashes fast RED
enough voltage available) and the unit does not switch on.
If during operation
occurs, the unit switches off
under voltage
and the LED illuminates RED.
If there is
when plugging in the unit, the LEDs start
over voltage
flashing
and
alternating and the unit will not
4x RED
1x GREEN
turn on.
If during operation
occurs, the unit switches off and
over voltage
the LED illuminates RED.
Maximum possible personal protection
is assured.