TROUBLESHOOTING:

PROBLEM
1. When switch K1 is pressed,
the indicator is not lit.
2. The red and yellow indicators
are lit at the same time, the oil
temperature does not increase.
3. The yellow indicator is not off,
but the oil temperature cannot
be checked.
4. The indicator is not lit,
temperature control is normal.
ELECTRICAL SAFETY REGULATIONS:
Comply with these basic standards:
- Match the mains voltage to the voltage specified on the rating plate;
- connection to a standard grounding socket;
- connection of an equipotential bonding system.
CAUSE
1. The power switch fuse is
damaged.
1. The electrical heating pipe
connection is loosening.
2. The electric heating pipe is burnt
out.
1. The controller is not working.
1. The indicator is broken.
SOLUTION
1. Replace the fuse.
2. Fix the power cord.
1. Tighten the fixed connection
screw of the electric heating pipe.
2. Replace the heating pipe.
1. Change the controller.
1. Change the indicator.