OG2000 - OG3000
The gas pipeline connection to the appliance must be done using a rigid
metal pipe and sealing connections.
It is possible to use a hose, but it must:
● Allow for inspection at all times.
● Be protected from possible contact with heatable parts (such as the
underside of the burners).
● Be protected from any stress (torsion, tensile, compression, etc.).
● Be protected from the moving parts of the cabinet (e.g. a drawer).
● Have a maximum length of 1.5 m.
● Be replaced before its expiration date.
Once connected, check the gas circuit seal by using a non-corrosive fluid to
detect any leaks. Do not use a soap and water solution. DO NOT USE AN
OPEN FLAME.

5.4 Electrical connections

CAUTION!
This appliance must be connected to a 12 V
a 2 x 0,5 mm
not exceed 2 meters. When wiring the appliance respect correct
polarity!
CAUTION!
Never connect the appliance to the main voltage (230 V~); this
would result in the ultimate destruction of the parts and a hazard
to the user.
To connect the appliance, use a double cable and connect it to the terminal
board identified with "+12 V
The red terminal is the positive pole, while the black terminal is the negative
pole.

5.5 Fixing

CAUTION!
This appliance must be fixed to the cabinet using the screws as
described in Fig. 5, page 6.
EN
cable is used for the connection, its length must
2
–", found on the back side of the appliance.
Installation
power pack. If
33