3. INSTALLATION

WARNING!
Refer to Safety chapters.

3.1 Before the installation

Before you install the hob, write down the
information below from the rating plate. The
rating plate is on the bottom of the hob.
Serial number ...........................
3.2 Built-in hobs
Only use the built-in hobs after you assemble
the hob into correct built-in units and work
surfaces that align to the standards.
3.3 Connection cable
• The hob is supplied with a connection
cable.
• To replace the damaged mains cable, use
the cable type: H05V2V2-F which
withstands a temperature of 90 °C or
higher. Speak to your local Service
Centre. The connection cable may only be
replaced by a qualified electrician.
N
L
One-phase connection - 230 V~
N
L
3.4 Attaching the seal - Integrated
installation
1. Clean the rabbets in the worktop.
230V~
Green - yellow
Blue and blue
Black and brown
WARNING!
All electrical connections must
be made by a qualified
electrician.
CAUTION!
Do not drill or solder the wire
ends. It is forbidden.
CAUTION!
Do not connect the cable without
cable end sleeve.
Two-phase connection
1. Remove the cable end sleeve from black
and brown wires.
2. Remove an insulation of the brown and
black cable ends.
3. Apply a new wire end sleeve of 1.5 mm²
on common cable end (special tool
required).
Cable cross section
400V 2~N
Two-phase connection - 400 V 2 ~ N
Green - yellow
Blue and blue
Black
Brown
2. Cut the supplied 3x10mm seal stripe into
4 stripes. The stripes must have the
same length as the rabbets.
N
L1
L2
N
L1
L2
ENGLISH