Herunterladen Inhalt Inhalt Diese Seite drucken

favero MICRO32 Handbuch Seite 15

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 17
CONTROL-BALL BOARD
8
7
Wire section
1mm
F I G . 2 C O N T R O L - B A L L
C O N N E C T I O N S
Even through operating with a 24 Volt insulating system,
the ball BOXes are equipped on the inside with a faston
d e v i c e i n o rd e r t o b e c o n n e c t e d t o t h e e l e c t r i c a l
grounding system.
There are BOXes for all kinds of games. See the section
on "ARTICLE CODES".
On the CONTROL-BALL board, a red light indicates:
flashing light:
the connection to the MICRO32 is okay
light always on:
the unit is not connected to the
MICRO32
light off:
the CONTROL-BALL is either broken or
has no power supply.
The CONTROL-BALL may also be connected to simple
ball containers in which the withdrawal of the tray turns on
a micro-switch. In this case, the game start takes place
automatically when the tray is taken out.
If you wish that automatic START to be a club operation,
you can regulate it before or within one minute of the tray's
extraction by pushing the START-CLUB button and then
the button for the table involved.
The two micro-switch wires are connected in the same
way as the two BOX wires.
6
5
4
3
2
1
1
2
min.
2
3
BOXes
FUSE T 315mA 250 Vac
COMMON-BOX
230 Vac 250mA
CONTROL-BALL
POWER-SUPPLY
NOTES
Containers of CONTROL-LAMP and CONTROL-BALL are
in material Class: IEC 650.
If the wiring is not fitted with protection from short circuits
and indirect contacts for all equipment, this must be
carried out by the client.
T h e M a n u f a c t u re r d e c l i n e s a l l re s p o n s i b i l i t y i f t h e
equipment is tampered with.
13
SERIAL
230V
CONNECTION
TO THE MICRO32
ENGLISH
LINE

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für favero MICRO32

Diese Anleitung auch für:

700

Inhaltsverzeichnis