Connection example of 1 door
Electromagnetic Lock 12V/600mA max
Power supply 14,2V
Adjust the output to 14.2 Vdc,
using screwdriver
See user manual
12V battery
This product herewith complies with requirements of EMC directive 2014/30/EU.
In addition it complies with RoHS2 directive EN50581:2012 and RoHS3 Directive 2015/863/EU.
1
2
Diode
1N4001
Door contact
Push button
Dip Switch
OFF
ON
Lan
Autonomous
Master
Slave
Run Led
Reader
- For doors equipped with 2 readers, one must be at address 0 and the other at address 1. If there is
only 1 reader, then it is recommended to be put with address 0.
- LIYCY cable, twisted pair, up to 80m. (5)
If more than 80 m. are needed, then termination resistors(120 ohm) may be required at both ends of
the RS485 line, while taking into consideration the lengths proposed on our web site.
- Alarm cable 2x0,22 (6)
Address 0
- The cross section of the cable depends on the current needed by the lock (7)
Note: The elevators relay boards (WS4-RB-12) are connected on the same RS485 lines as the readers.
www.xprgroup.com
Box Tamper
Led Comm
Net
Reader
Address 1