Exhaust air fan Aero_aH 100 with integrated room and cellar dehumidification control

4.2. Intended use

The device is only intended for domestic use and
similar purposes.
The unit is designed for dehumidification of cellars,
storage rooms, showrooms, offices, changing
rooms and similar rooms up to a size of
2
approximately 25 m
.
Operation is only permitted for:
Permanent installation inside buildings
Installation on a wall or ceiling
Air ducting via shaft or pipe
Electrical flush-mounted connection
Full functionality is only achieved with the included
outdoor climate sensor (closing flap with integrated
outdoor climate sensor).
ATTENTION: Restricted use in case
of structural defects.
In case of structural defects, water
often penetrates basement rooms via floors
and walls.
In such cases, the ventilation system Aero_aH
100 can be used as a supplement for basement
dehumidification. The unit supports brickwork
drying through controlled air exchange but
cannot achieve complete dehumidification by
itself.
ATTENTION: Risk of damage to the
building fabric if ventilated
manually.
Excessive manual ventilation can lead to room
humidification when the outdoor humidity is
high. Therefore, it is essential to pay attention
to the duration of ventilation when using an
external switch.

4.3. Forseeable misuse

ZILA does not assume any liability for damage
caused by improper use. Do not use the unit under
any circumstances:
In individual ventilation systems according to
DIN18017-3
Near flammable materials, liquids or gases
For conveying chemicals, aggressive gases or
vapours
In explosive atmospheres
In outdoor areas

4.4. Technical data

Technical specifications can be found in the product
specific data sheet on our website
4.5. Operating and environmental
conditions
The
medium's
permitted is + 40 °C.
When
operating
fireplaces, sufficient supply air must be
provided.
The maximum pressure difference permitted
per flat is 4 Pa.

5. Safety instructions

5.1. General

• Assembly and electrical connection
may
only
electricians in accordance with
chapter 1.
• Read these mounting and operating
instructions
commissioning.
• Only connect unit to permanently
wired electrical installations with
NYM-O or NYM-J (3 x 1.5 mm² or 5 x
1.5
mm²)
disconnection device required with
1019-1-0002 Handbuch 31.01.2021_JUSC_Aero_aH100|
www.zila.de/en
maximum
temperature
with
air-dependent
be
undertaken
carefully
before
cables.
Mains
.
by
16