Herunterladen Inhalt Inhalt Diese Seite drucken

Understanding The Product's Indicators - FireAngel CO-9X-10-EU Benutzerhandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

UNDERSTANDING THE
PRODUCT'S INDICATORS
The higher the concentration of carbon monoxide detected by the alarm, the
quicker it will respond . When sufficient carbon monoxide is detected a loud
audible signal (85 dB at 1m/3 feet) will be emitted and the Alarm LED will
flash red once every second .
The alarm will sound:
• Between 60 and 90 minutes when exposed to a minimum of 50ppm of CO .
• Between 10 and 40 minutes when exposed to a minimum of 100ppm of
CO .
• Within 3 minutes when exposed to a minimum of 300ppm of CO .
Fault / End of Life signal:
The unit continuously checks the settings of its sensor and circuitry . If
any of these settings are found to be incorrect or if battery becomes low
then the alarm will emit a single audible chirp once per minute for up to
30 days . IMPORTANT: This does NOT mean that the alarm has detected
carbon monoxide .
If the product is still within warranty then contact technical support . If the
product is no longer in warranty replace immediately!
IMPORTANT: The selected battery was chosen to provide power beyond
the lifetime of the product, in particular the sensor (under normal operating
conditions) . The operational life of the sensor is 10 years, for this reason, the
alarm should be replaced after 10 years from the date of installation .