• If the domestic premises is a bedsit (a single room serving as both sitting
and bedroom) then the alarm should be put as far from the cooking
appliances as possible but near to where the person sleeps .
• If the appliance is in a room not normally used (for example a boiler
room), the alarm should be put just outside the room so that the alarm
may be heard more easily . Alternatively, a remote alarm siren
may be connected to a type A alarm located in a room(s) containing a
fuel-burning appliance .
Where in the room should I place the alarm?
Alarms located in the same room as a fuel-burning appliance, for both wall
and ceiling mounted alarms the following applies:
a . The alarm should be at a horizontal distance of between 1m and 3m from
the potential source .
b . If there is a partition in a room, the alarm should be located on the same
side of the partition as the potential source .
c . Carbon monoxide alarms in rooms with sloped ceilings should be located
at the high side of the room .
In addition to the above the following must be observed if the alarm is
located on a wall:
a . It should be located close to the ceiling;
b . It should be located at a height greater than the height of any door or
window;
c . It should be at least 150mm from the ceiling .