Important Note
This user manual contains important information for the installation and use
of your carbon monoxide alarm. Please read it carefully and save it for future
reference.
Introduction
This device is a battery-powered carbon monoxide alarm with advanced features
and is for domestic use only. Please note that this device does not sense smoke,
heat, flames or other hazardous gases.

Package Contents

1 x CO03A Carbon Monoxide Alarm
3 x LR6 AA 1.5V Batteries
2 x Screws
2 x Anchor Plugs
1 x User Manual
2

Technical Specifications

Power source
Sensor type
Type of gas sensed
Alarm activation
Operating temperature
Ambient humidity
Horn level
Product size
Product life
Where to Locate
1. The carbon monoxide (CO) alarm should be located outside each separate
sleeping area in the immediate vicinity of the bedrooms. To ensure the most
effective use of the CO alarm, it should be fitted at least 1.5 meters (5 feet)
above floor level. It should be at least 15 cm (6 inches) away from the ceiling
and 30 cm (12 inches) away from any adjacent wall. Make sure that there is no
obstacle between the alarm and any potential CO source (e.g. gas boiler or
gas-fuelled heating appliance).
2. For the best protection, a carbon monoxide alarm should be installed in every room
and hallway in your home, apart from the locations listed in the next sections.
3 LR6 AA 1.5V
Electrochemical
Carbon monoxide
30 to 49 ppm (120 minutes)
50 to 99 ppm (60 to 90 minutes)
100 to 299 ppm (10 to 40 minutes)
Above 300 ppm (0 to 180 seconds)
-10℃ to +40℃
15% to 90%
85 dB at 1 m (3.3 feet)
127 mm x 75 mm x 35 mm
3 years