3.1 Mounting onto TS 35 DIN rails
(Page 44, Fig. 1)
3.2 Pluggable electronic components for range alteration
(depending on model)
(Page 44, Fig. 2)
1. Remove connector, (depending on model either screw-type
or tension clamp).
2. Press locking clips on both sides of the enclosure.
3. Pull out the circuit board.
Warning!! The circuit board can only be inserted in one position.
The connectors have been coded by the manufactur-
er, ensuring that they cannot be reversed.
3.3 Pluggable cross-connections for voltage supply
(Page 45, Fig. 3)
A maximum feed through of 2 A is possible.
If a signal conditioner is accidently rotated through 180°, the
cross-connection cannot be inserted.