Herunterladen Diese Seite drucken

Operation; Maintenance - S&P SILENT DESIGN Serie Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für SILENT DESIGN Serie:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 17
SILENT-100 CZ DESIGN 12V
For these models use the diagram fi g.11
SILENT CRZ DESIGN
This model is provided with an adjustable
over-run timer. The timer allows the fan to
continue to operate for the selected period
after the switch has been turned off (fi g.6).
Model provided with a 4 positions adjust-
able electronic timer: Fig.5 shows how to
connect the fan with timer utilising the
same switch as for the lighting circuit.
To set the timer, turn the potentiometer on
the printed circuit board as (fi g.7).
- To reduce the "run on" time, turn anti-
clockwise (min. 1 minute)
- To increase the "run on" time, turn
clockwise (max: 30 minutes).
SILENT CHZ DESIGN
Models provided with an electronic humidi-
stat which can be adjusted from 60% to 90
% RH (relative humidity) and with a timer,
adjustable between 2 and 20 minutes.

Operation

Case 1: Automatic operation (fi g.9)
In automatic operation, the humidistat
causes the extractor to operate automati-
cally when the humidity level in the room
is higher than the set level. The extractor
will stop automatically when the humidity
drops below the selected level and after
the selected period set on the timer.
Case 2: Automatic operation as in case 1
with the facility to override the hygrostat
by means of the light switch (fi g.8), when
the humidity level in the room is lower than
the selected level. In this case, the extrac-
tor continues to operate for the selected
period set on the timer after the switch
light has been switched off.
ATENTION: When the humidity rate is
above the selected value, the automa-
tic option takes precedence over the
manual and the unit cannot then be
switched off using a switch.
The desired humidity level is selected
by means of a potentiometer "% Hr"
positioned on the printed circuit board
(fi g.10) and accessible once the grille (1)
has been removed.
- To increase the humidity setting turn
anticlockwise (min.60 %)
- To reduce the humidity setting turn
clockwise (max. 90 %)
To set the timer, turn the potentiometer
"t min." on the printed circuit board
(fi g.10):
- To reduce the "run on" time, turn anti-
clockwise (min. 2 minutes)
- To increase the "run on" time, turn
clockwise (max: 20 minutes).
SILENT-100 CHZ / CRZ DESIGN 12V
For these models use the diagram fi g.12
User instruction
This appliance can be used by children
aged from 8 years and above and
persons with reduced physical, sensory
or mental capabilities or lack of experien-
ce and knowledge if they have been
given supervision or instruction concer-
ning use of the appliance in a safe way
and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not
be made by children without supervision.

Maintenance

The extractor fan only requires periodical
cleaning using a cloth lightly impregnated
with a soft detergent.
After Sales Service
We recommend you not to try to dismantle
or remove any other parts than those men-
tioned as any tampering would automatica-
lly cancel the S&P guarantee. If you detect
any fault, contact your S&P dealer.
S&P reserves the right to alter specifi ca-
tions without notice

Werbung

loading