Herunterladen Inhalt Inhalt Diese Seite drucken

behnke 10-IP Serie Anleitung Seite 42

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Instructions for Behnke SIP 2.0
GB
Hardware
Potential-free outs (relays), ins
The SIP remote station can hold up to two
potential-free outs (Relay 1
tact, relay 2
, changeover contact) via screw
terminals. Additionally, the SIP remote station
provides an electrically isolated input, which
is connected using screw terminals
The relays load maximum is 2 A at 30VDC or
0.5 A at 40VAC.
The alarm input triggers upon applying an
input voltage between 10 and 15 V=, the
maximum input voltage is 15 V=. Please bear
in mind the polarity!
42
All manuals and user guides at all-guides.com
, closing con-
.
Grounding connection
Important: In case the electrical circuit is type
TNV-1, an EARTH must be connected to the
GND screw terminal
circuit is usually used for installations in a
pillar, where the Ethernet cable is installed
outside the building. In case the Ethernet
cable remains within the building, the SIP
remote station does not require a grounding
connection.
The grounding terminal
here.
www.behnke-online.com
. A type TNV-1 electrical
must not be used