DESCRIPTION.
SET/RESET switch for emergency call system, location in the
dark, 2 NO relay outputs 5 A 250 V~ for acoustic and optical
signals, supply voltage 12 V~ 50-60 Hz or 12-24 V d.c. (SELV)
- 2 modules
CHARACTERISTICS.
• supply voltage:
- 12-24 V d.c. ±10%
- 12 V~ ±10% 50-60 Hz
• absorption: approximately 100 mA with active alarm outputs
RL1 and RL2
• front switch: SET push button
• two-colour LED:
- green: equipment supplied
- red: alarm activated
• input:
- normally closed connected to positive (+) terminal for SET
function
- normally closed connected to positive (+) terminal for RESET
function
• alarm output RL1: relay NO 5 A 250 V~ with double insulation
with respect to power supply and push buttons
• alarm output RL2: relay NO 5 A 250 V~ with double insulation
with respect to power supply and push buttons
• controllable loads:
- purely resistive loads
: 5 A
- incandescent lamps
: 500 W
- magnetic core transformers for very low voltage incandescent
lamps (for example, halogen lamps)
• not suitable to control fluorescent lamps directly

OPERATION.

• When the mains supply voltage is present on the device, the
two-colour LED lights up green.
• Pressing the SET push button on the equipment or an exter-
nal SET push button triggers call mode (alarm)
- the two-colour LED lights up red and starts blinking.
- alarm relay RL1
is asserted for 3 seconds approx.: gener-
ally it is connected to a bell/buzzer.
- alarm relay RL2
is asserted for 5 seconds approx. and
then intermittently at intervals of 1 second approx.: it is gener-
ally connected to a red prismatic lamp.
• The alarm state is cancelled by issuing the RESET switch
from one of the external push buttons.
• Simultaneously pressing the SET and RESET push buttons
enables the SET function.
• There can be any number of SET or RESET push buttons,
which must be connected in series
INSTALLATION RULES.
The installation must be done according to rules for electrical
installations of buildings in force in the country where the prod-
ucts are installed.
The output circuit must be protected against overcurrents by
installing a fuse with a rated breaking capacity of 1500 A with
rated current not exceeding 5 A.
CONFORMITY TO STANDARDS.
Directive BT
Directive EMC
Normas EN 60669-2-1
Viale Vicenza, 14 - I 36063 Marostica VI
Tel. +39 0424 488 600 - Fax (Export) +39 0424 488 709
www.vimar.com
Idea
Plana
16643
14183
CONNECTIONS.
Connection.
With a d.c. supply voltage, the SET and RESET push buttons must be connected to positive (+)
L
N
12-24 V d.c.
12 V~
The minimum installation.
: 500 W
ATTENTION: The minimum installation configuration requires at least one RESET push button and, if there are no external SET
push buttons, a wire connection between the SET output and the positive terminal.
With a d.c. supply voltage, the SET and RESET push buttons must be connected to positive (+)
L
N
12-24 V d.c.
12 V~
-
+
+
RESET
S
SET
-
+
+
RESET
S
Instruction sheet
250 V~ max
-
R
250 V~ max
-
R
ENGLISH

Werbung

loading

Diese Anleitung auch für:

Eikon 19183Eikon 16643Eikon 14183Eikon arke serieEikon plana serieEikon idea serie