3) Using the table, work out the opening size (minimum
opening for your window) from the extraction power and
window size.
4) While the window is in the titled position, measure the
upper inner gap size of the window in cm. The gap size
of your window must not be below the opening size
calculated! The bigger the gap or window opening, the
better.
5) If the gap size of the window is less than the permissible
value for the opening size according to the table, the
window may only be able to achieve the required
opening size in the pivot position. There must also be a
minimum gap when the window is in the pivoted posi-
tion. The window contact shall be positioned in such a
way as to ensure the minimum gap size. We recommend
you ensure the minimum gap size using a spacer.
Preparation
Install the transmitter (6) and magnet (7) to the window
frame and the window casement in such a way that the
distance from the magnet and transmitter is less than 7 mm
on all sides when the window is closed. To adjust this, use
the washers supplied (U).
We recommend that you mount the transmitter and magnet
using double-sided tape until it is ultimately secured in place
and only screw everything when installation is complete.
Installation for tilted position
The transmitter and magnet must be mounted on the hinge
side of the window. This means on the right for a right-
hinged window and on the left for a left-hinged window.
AS-5030_I-Manual_150x180_Fin1.indd 16
The mounting point should be selected so that the „open
window" signal is only given if the necessary opening size
is reached in accordance with the table. When pivoting the
window, the magnet must always be less than 7 mm from
the transmitter so that the transmitter always recognises the
window as being closed! You should however make sure that
the transmitter and magnet cannot touch when the window
is pivoted.
Installation for pivoted position
The sensor and magnet must be mounted on the side where
the tilt hinge is (usually below). The mounting point should
be selected so that the „open window" signal is only given if
the necessary opening size is reached in accordance with the
table. When tilting the window, the magnet must always be
less than 7 mm from the transmitter so that the transmitter
always recognises the window as being closed! You should
however make sure that the transmitter and magnet cannot
touch when the window is tilted.
1) Fix the magnet in place at the designated location using
the double-sided adhesive pad supplied.
2) Fix the window contact onto the window with the
double-sided adhesive pad supplied.
WARNING: The distance between the transmitter and
the magnet must not exceed 7 mm!
3) Once all functions have been tested successfully,
the transmitter and magnet must be screwed to the
window/window frame. For this purpose, there is a hole
prepared in the battery compartment of the transmitter
and in the lower part of the magnet housing. The
transmitter and magnet can therefore be screwed to the
window/window frame. This prevents the transmitter
and magnet from accidentally falling off!