TROUBLE SHOOTING TIPS

BREAKDOWNS AND FAULTS
G
TROUBLE
Stop the pool heat pump immediately if one of the following faults occur. Disconnect the power
and contact your supplier.
• Fuse blows frequently or circuit breaker trips frequently.
• Other objects or water penetrate the pool heat pump.
• Other abnormal situations.
In the event of a problem, the heat pump's screen displays an error code instead of temperature indications.
Please consult the table below to find the possible causes of a fault and the actions to be taken.
Code
P1
P3
P5
P7
E3
E6
G
NOTE!
If problem persists, contact a local dealer or your nearest customer service center. Provide them
with a detailed description of the unit malfunction as well as your model number.
If the trouble has not been corrected, please contact your supplier. Be sure to inform them of the detailed
malfunctions and unit model.
G
NOTE!
Reparation of the device should only be done by an authorized air conditioning engineer.
Q_man_SPHP 130 ('21) V6.indd 47
Q_man_SPHP 130 ('21) V6.indd 47
Fault
Water intake temperature sensor
malfunction
Evaporator temperature sensor
malfunction
External temperature sensor
malfunction
Antifreeze protection
Flow sensor malfunction
Low pressure protection
The unit stop working without
error code
Possible causes
Sensor badly connected
Sensor defective
Defective control panel
Same causes as P1
Protection activated when the
ambient temperature is too low.
Insufficient water in heat exchanger
Defective water flow sensor
Defective control panel
Insufficient refrigerant gas
Pressure switch not connected well
or defective
Control panel defective
Insufficient water in heat exchanger
Defective control panel
Action
Reconnect sensor
Replace sensor
Replace control
panel
Same actions as P1
No intervention is
necessary
Check your water
circuit operation
Replace water flow
switch
Replace control
panel
Recharge refrigerant
gas
Connect of replace
the pressure switch
Replace control
panel
Check your water
circuit operation
Replace control
panel