8.0

Warranty limit

The warranty period for the Inverter 500 and
Inverter 1000 is 2 years.
The warranty will be considered void if the unit has
suffered any physical damage or alteration, either
internally or externally, and does not cover damage
arising from improper use like:
-
Reverse of battery polarity
-
Inadequate input voltage (over voltage)
-
Back-feed of the inverter output by public
network , generator or any other source.
-
Mechanical shock or deformation specially by
transport due to an inadequate package.
-
Contact with liquid or oxidation by condensation
-
Use in inappropriate environment (dust,
corrosive vapour, humidity, high temperature,...)
This warranty will not apply when the product has been
misused, neglected, improperly installed, or repaired
by anyone other than Schüco International KG or a
company authorised by Schüco International KG. In
order to qualify for the warranty, the product must not be
disassembled or modifi ed.
9.0

Limits of manufacturer liability

Schüco International KG cannot control the installation,
use and maintenance of the inverter. Thus, we are
not responsible for damages, costs or losses resulting
from an installation which is not in accordance with the
regulations or inappropriate use or maintenance.
The customer is always responsible for the use of the
Schüco International KG inverters.
This device has not been designed and is not warranted
for use in life support apparatus or any other critical
device with potential risks of important harm to people or
to the environment. We do not accept any responsibility
for any violation of patent rights or other third person
rights resulting from the use of the inverter.
Schüco International KG keeps the right to modify their
products without previous notice.
14
10.0
Tecnical data
MODEL
Battery voltage (V)
Input voltage (V)
Continuous /
30' power (VA)
Stand-by / ON @ no
load (W)
Maximum effi ciency
(%)
Dim. H x B x T (mm)
Weight (kg)
Load detect.
(Stand-by)
Output voltage
Frequency
Ventilation
Overheating protection
Overload protection
Short circuit protection
IP protection index
Cos φ
231 575
Inverter 500 Inverter 1000
24
21 - 32
500/600
1000/1300
0.3 / 3.8
0.4 / 10
94
94
142x240x84
142x428x84
4,5
8,5
Adjustable from 1-20 W
Sine wave 230V +/-5%
(115V +/-5%)
50 Hz +/- 0.05 %
(60 Hz +/-0.05%)
From 45° C
yes
yes
yes
IP23
0.1-1
09.2008