Herunterladen Inhalt Inhalt Diese Seite drucken

Use; Control And Indicators - Schüco Inverter 500 Montage- Und Bedienungsanletung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
PV Modul
Charge Regulator
Battery 2 x 12V or 12 x 2V Serie
Inverter 500
230 VAC
PV Modul
Charge Regulator
Battery 2 x 12V or 12 x 2V Serie
Inverter 1000
230 VAC
Abb. 1.2: Connections Inverter 500 and
Inverter 1000
12
4.0

Use

4.1

Control and indicators

Control switch On/Off
There is a switch on the bottom plate of the inverter
to activate or deactivate it. Use this function to save
the energy of the batteries when you are not using the
inverter.
Green indicator
A green light (LED) on the bottom plate of the inverter
indicates its function mode:
4.2
Acoustic indicator
The inverter has an acoustic indicator for the following
instances:
Intermittent beep:
there is a failure in the inverter and the output voltage
will be interrupted.
Possible failures:Overheat: the acoustic indicator
beeps 3 ºC before cutting the load. If the temperature
reaches its normal level, the voltage in the output is not
interrupted.
Low battery voltage: the indicator beeps for a minute
before the interruption. If the voltage of the battery rises,
the output voltage is not interrupted.
Continuous beep for two seconds:
you have pressed the ON/OFF switch to restart the
inverter. The load in the output will be immediately
present after the acoustic signal.
231 575
LED off
the 230 V voltage is NOT present
in the output, the inverter is off.
LED illuminated
a 230 V voltage is present in the
output, the inverter is on.
LED blinking
No load (stand-by)
LED blinking
the inverter has been disconnected
due to an alarm; the inverter will
resume function when the failure
has disappeared (see the failure
table).