PROGRAMMING

This paragraph contains general guidelines on how to
programme the EasyOne Sx1 weld control unit. Specific
instructions on the adjustments of different welding tools are
contained in the relative paragraphs.
Control unit name, model, programme version and operating
frequency are displayed when turned on.
SW VER. 1.0
The control unit has two types of adjustments: the manual one
and the "synergic" programmes optimized for executing the most
common jobs.
Use buttons ß and Ý to select the required programme.
1.5 30%
Use buttons Ü and Þ to switch from the weld parameters
programming to the setting of the auto start function.
AUTOSTART
ON 0.3s
OFF
The diagram in figure 1 (page 48) shows all the programming
pages.
12
43 %
2.0
45%
12
43 %

MANUAL MODE

In this mode the operator adjusts the required time and current
values. This mode is used for all those jobs for which a specific
programme has not been envisaged.
In order to change the displayed values, press button + or –; the
time parameter symbol flashes; use buttons + and – to
programme.
Use buttons ß and Ý to switch from time adjustment to current
adjustment and vice versa. The icon of the parameter you
changed will flash.
The bar indicator on the right-hand side gives an instant view of
the adjustment.
TIME AND CURRENT SETTING MODE ("SYNERGIC")
The operator recalls preset weld programmes, dedicated to
carrying out the set jobs, as follows:
Use buttons + and – to finely adjust the weld
parameters. A central zero bar indicator shows the fine
adjustment. The control unit automatically determines
the time and current changes through synergic curves.
The time and current values that will actually be used
are displayed at the bottom.
1.5 30%
1.5 40%
12
43 %
6.0 80%
1.5 40%