3.6 Connecting the Cash Drawer

1.
Turn off the power.
2.
Confirm the orientation of the cash drawer kick-out cable connector and connect it
to the cash drawer kick-out connector at the back of the printer.
3.
Remove the screw for the ground wire.
4.
Screw the cash drawer's ground wire to the body of the printer.
Cash drawer kick-out
Cash drawer kick-out cable
connector
CAUTION
 Connect only the cash drawer kick-out cable connector to the cash drawer kick-out
connector. (Do not connect a telephone line.)
 Signals cannot be output from the cash drawer kick-out connector while printing.
(1) Connector pin configuration
No.
Signal
1
FG
Frame ground
2
DRAWER1
Cash drawer 1 drive signal
3
DRSW
Cash drawer switch input
4
VDR
Cash drawer drive power supply
5
DRAWER2
Cash drawer 2 drive signal
6
GND
Signal ground (common ground on
circuits)
(2) Electric characteristics
1)
Drive voltage: 24 VDC
2)
Drive current: Approx. 1 A max. (not to exceed 510 ms.)
3)
DRSW signal: Signal levels: "L" = 0 to 0.8 V, "H" = 2 to 3.3 V
(3) DRSW signal
DRSW signal status can be tested with the DLE+EOT, GS+a, or GS+r
command or at pin 34 on the parallel interface port.
connector
Function
— 30 —
Ground wire
Screw for ground
wire
Connector used:
TM5RJ3-66 (Hirose) or
equivalent
Applicable connector:
TM3P-66P (Hirose) or
equivalent