switch the device on again while the insertion tool is stalled, as doing
so could trigger a sudden recoil with a high reactive force. Determine
why the insertion tool stalled and rectify this, paying heed to the
safety instructions.
The possible causes may be:
• it is tilted in the workpiece to be machined
• it has pierced through the material to be machined
• the power tool is overloaded
Do not reach into the machine while it is running.
The insertion tool may become hot during use.
WARNING! Danger of burns
• when changing tools
• when setting the device down
Chips and splinters must not be removed while the machine is
running.
Clamp your workpiece with a clamping device. Unclamped workpi-
eces can cause severe injury and damage.
Before doing any work on the machine, pull the plug out of the
socket.
GB

MAINS CONNECTION

Connect only to single-phase AC system voltage as indicated on
the rating plate. It is also possible to connect to sockets without an
earthing contact as the design conforms to safety class II.
Appliances used at many different locations including wet room and
open air must be connected via a residual current device (FI, RCD,
PRCD) of 30mA or less.
Make sure the machine is switched off before plugging in.
Under the effect of extreme electromagnetic interferences from
the outside, temporary variations in the speed of rotation could
arise in particular cases.
SPECIFIED CONDITIONS OF USE
The rotary pneumatic hammer can be used for hammer drilling,
chiselling in stone and concrete and drilling in wood, metal as well
as plastic.

MAINTENANCE

The ventilation slots of the machine must be kept clear at all times.
If the supply cord of this appliance is damaged, it must only be
replaced by a repair shop appointed by the manufacturer, to avoid
hazardous situations.
Important note! If the carbon brushes are worn, in addition to
exchanging the brushes the tool should be sent to after-sales
service. This will ensure long service life and top performance.
Use only Milwaukee accessories and Milwaukee spare parts. Should
components need to be replaced which have not been described,
please contact one of our Milwaukee service agents (see our list of
guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. Please
state the machine type printed as well as the six-digit No. on the
label and order the drawing at your local service agents or directly
at: Techtronic Industries GmbH, Max-Eyth-Straße 10, 71364 Win-
nenden, Germany.
English
10
Downloaded from
www.Manualslib.com
manuals search engine
EC-DECLARATION OF CONFORMITY
We declare under our sole responsibility that the product described
under "Technical Data" fulfills all the relevant provisions of the
directives
2011/65/EU (RoHS)
2006/42/EC
2014/30/EU
and the following harmonized standards have been used.
EN 60745-1:2009 + A11:2010
EN 60745-2-6:2010
EN 55014-1:2006 + A1:2009 + A2:2011
EN 55014-2:1997 + A1:2001 + A2:2008
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 50581:2012
Winnenden, 2016-03-25
Alexander Krug / Managing Director
Authorized to compile the technical file
Techtronic Industries GmbH
Max-Eyth-Straße 10, 71364 Winnenden, Germany
SYMBOLS
CAUTION! WARNING! DANGER!
Always disconnect the plug from the socket before carrying
out any work on the machine.
Please read the instructions carefully before starting the
machine.
Accessory - Not included in standard equipment, available
as an accessory.
Do not dispose of electric tools together with household waste
material. Electric tools and electronic equipment that have
reached the end of their life must be collected separately and
returned to an environmentally compatible recycling facility.
Check with your local authority or retailer for recycling advice
and collection point.
Class II tool Tool in which protection against electric shock does
not rely on basic insulation only, but in which additional safety
precautions, such as double insulation or reinforced insulation,
are provided. There being no provision for protective earthing or
reliance upon installation conditions.
European Conformity Mark
EurAsian Conformity Mark

Werbung

Inhaltsverzeichnis