Setting the Time Manually
It is necessary to set the time manually if the clockwork is to be used beyond the range of the
DCF signal.
To set the time manually, press the M.SET button for 3 seconds.
• As soon as the minute hand starts to run, you can set the time manually.
• Press the M.SET button briefl y, to adjust the time in minute steps, or keep the M.SET button
pressed, to adjust the time continuously.
• When the M.SET button is not pressed any longer, the set time is automatically accepted
after 8 seconds, and the manual time setting mode is exited.
Resetting the clock movement
Use this function if the clock movement no longer responds to keystrokes or in the event of
other malfunctions.
In this case, all of the previously received DCF data is deleted.
• To reset the clockwork, press the RESET button with a sharp-pointed object (e.g. a pen).
• The hands move to the receiving position (12:00) and the clockwork tries to detect the DCF
signal.
• Wait for about 3-12 minutes, until the current time is indicated.
Storage of the clock movement
If you want to store the clock movement, but it has been used already, you should lock it in
place at the 12:00 position using the locking pin.
• Press the RESET button with a sharp object (e.g. a pen).
• The hands move to the reception position (12:00 o'clock).
• Remove the battery.
• Plug the locking pin into the corresponding borehole on the rear of the casing. You should be
able to insert the pin into the borehole without applying any force.
• Secure the pin with an adhesive strip so that it cannot fall out accidentally.
Maintenance and Cleaning
To clean the clock movement, a dry, soft and clean cloth is suffi cient.
Do not use any chemical cleaning agents, as they can corrode and discolour the plastic casing.

Troubleshooting

The clock movement does not synchronise or only has temporary reception:
• The distance to the DCF transmitter is too long or restricted by geographical conditions.
• Relocate the product; switch off interfering devices such as TV sets, computers or microwave
ovens.
• Avoid a location in the vicinity of large metal surfaces, which may shield the radio signals.
Windows with a vapour deposited metal layer can also infl uence the signal reception.
• Place the clock movement at the window for synchronisation, and align the front or back side
in the direction of Frankfurt (Germany).
• Leave the clock movement switched on over night to avoid atmospheric interference.
Disposal
a) Product
Electronic devices are recyclable waste materials and must not be disposed of in the
household waste!
Dispose of an unserviceable product in accordance with the relevant statutory regu-
lations.
Remove the battery if there is one inserted and dispose of it separately from the
product.
b) Normal and Rechargeable Batteries
As the end user, you are required by law (Battery Ordinance) to return all used batteries/
rechargeable batteries; disposal of them in the household waste is prohibited.
Batteries / rechargeable batteries containing harmful substances are marked with
the following symbols, to indicate that disposal in the domestic waste is forbidden.
The symbols of the relevant heavy metals are: Cd = Cadmium, Hg = Mercury, Pb =
Lead.
You can return your used batteries/rechargeable batteries free of charge to the offi cial collec-
tion points in your municipality, in our stores, or anywhere where batteries or rechargeable
batteries are sold.
You thereby fulfi l your statutory obligations and contribute to the protection of the environment.
Technical Data
a) Battery data
Type .................................... 1.5 V/DC (AA/mignon battery)
Battery service life ............. approx. 1.5 to 2 years
b) Mechanical data
Item No.
Shaft
Hand borehole
(mm)
(mm)
43 98 02
12
3.2 / 5.1
43 98 03
14.5
3.2 / 5.1
43 98 14
17
3.2 / 5.1
43 98 15
12
3.2 / 5.1
43 98 29
14.5
3.2 / 5.1
43 98 41
17
3.2 / 5.1
Declaration of Conformity
We, Conrad Electronic, Klaus-Conrad-Straße 1, 92240 Hirschau, hereby declare that this prod-
uct adheres to the fundamental requirements and the other relevant regulations of Directive
1999/5/EC.
The Declaration of Conformity for this product can be found at www.conrad.com
These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1,
D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfi lming,
or the capture in electronic data processing systems require the prior written approval by the editor.
Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in
technology and equipment reserved.
© Copyright 2013 by Conrad Electronic SE.
Clock-face thick-
Mounting bore-
ness (mm)
hole (mm)
max. 1
8
max. 3.5
8
max. 4.5
8
max. 2
8
max. 3.5
8
max. 4.5
8