Herunterladen Inhalt Inhalt Diese Seite drucken

Imer Group KOINE 3 Handbuch Für Bedienung, Wartung Und Ersatzteile Seite 30

Verputzmaschine
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 34
INCONVENIENTI
Machine does not start
Water
Water pressure too low: the gauge shows pressure below 2 bar
(green lamp on?), the display shows the text H
Machine does not start
Material
- Product too dry in mixing chamber
(mortar pump seized? red lamp on?)
Machine does not start
Grid
-Grid not inserted completely, the display shows the text Bloc
Machine does not start
Air
- The air pressure, with jet valve completely open, does not fall
below the minimum pressure value on the machine pressure switch
(table 1)
Machine does not start
Electrical current
and compressor does
- No current delivered to connector of site panel
not start and the blue
(fuses?)
light is OFF
- No power delivered to machine
(defective connector connection? loose cable?)
- Main switch not ON
Machine does not start
Electrical current
but compressor starts
- Start selector switch not in correct position
- Mixing chamber open
(start/stop pushbutton lamp on?)
- Mortar pump motor connector not inserted
(start/stop pushbutton lamp on?)
- Low water pressure switch trips on start-up
(water pump switched on ?see also "machine does not start due to
water)
Machine does not stop
Air
and/or compressor
- Air hose defective
does not stop
(hose cut? Air leaks from couplings?
- Compressor air supply low
- Jet air valve faulty (blocked in open position)
Machine stops after
Water
starting up
- Intake filter clogged
- Pressure reducer filter clogged
- Water hose too long and/or too narrow
- Water supply insufficient
IMER INTERNATIONAL S.p.A.
KOINE 3
CAUSE
O
2
30
RIMEDI
- Check that water is delivered from the supply
hose
- Check that the water filter is clean
- Check that the water pump is switched on
- If the pump collects from a tank, check that it has
been primed and there are
no leaks from couplings
- Initial start-up not performed correctly (see
para.11)
- Water flow rate setting too low (see para.11)
- No water delivered to mixing chamber
(water inlet obstructed, water solenoid valve
malfunction)
-Check that the grid is positioned correctly
- Check that the air hose is not bent or obstructe-
do
- Check that the jet nozzle is perfectly clean
- Check points listed alongside
- Check points listed alongside
- Check the air hose and couplings in particular
and replace if necessary
- Check air filter (see para. 12)
- Check compressor relief valve
- Check points listed alongside: clean filters,
check for adequate flow rate from the water hose
(at least 10-12 l/min if working with lime-cement
based plaster, at least 15-20 l/min with gypsum
based plasters) and replace hose if necessary or
collect water from an auxiliary tank

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

110600711060081106009Koine 3l

Inhaltsverzeichnis