DIY-12.book Seite 33 Freitag, 24. Februar 2006 3:51 15
DIY-12
7.2
You will find a summary of the wiring in the circuit diagram in fig. 5, page 3.
No.
1
2
3
4
5
6
7
8
9
rt
ge
gn
sw
gr
➤ Connect the black cable to earth (terminal -31).
➤ Connect the red cable to a cable with a permanent +12 V charge
➤ Connect the yellow cable to a connected positive terminal (terminal 15).
➤ Optionally, connect the green cable to the bonnet contact switch
➤ Optionally, connect the door contact switch kit (optional accessory) to the
➤ If you want to deactivate the acknowledgement tones when you arm or
Downloaded from
www.Manualslib.com
Connecting the alarm system
Explanation
Terminal 30, +12 V
Terminal 15, switched +12 V
Compact alarm unit
Cable for deactivating acknowledgement tones
Status LED
Cable to bonnet contact switch
Door contact switch kit
Original cable to boot contact switch
Original cable to door contact switch
Red
Yellow
Green
Black
Grey
(terminal +30).
(accessory).
green cable as shown in the circuit diagram.
disarm the alarm system, connect the grey cable to the black cable or
connect it to earth.
manuals search engine