the lighting is switched off completely.
The device can run either in night mode or in auto­
matic mode. These two modes cannot be activated at
the same time.
Active Restart Function
Enables operation via a controllable socket or
timer. If the power supply is interrupted, the
device remembers all settings and continues to
run automatically with the same settings as
soon as the power supply is restored.

8. Cleaning and care

Cleaning the combination filter
Regular cleaning of the combination filter (once
a month) guarantees trouble­free operation of
the Airfresh Clean 400 and maximum indoor air
quality.
Proceed as follows:
1. Switch off the device before each cleaning
and unplug the mains plug.
2. Turn the unit upside down and place it on a
firm surface (2.1).
3. Open the screw cap on the bottom of the
unit (2.2).
4. Lift off the bottom of the housing (2.3).
5. Remove the Soehnle HEPA combi filter (2.4)
and clean it.
The prefilter is attached to the filter with Velcro. Clean
the prefilter under running water. Make sure the prefilter
is dry before reattaching it to the Soehnle HEPA
combi filter. The Soehnle HEPA combination filter should
only be cleaned with a vacuum cleaner.
6. Reinsert the filter and make sure it is properly
inserted.
7. Close the device (3) and tighten the screw
cap. Turn the device back the right way
round and place it on a firm surface.
Make sure that the base plate is correctly inserted and
locked into the locking guide. Also note the arrow marking
on the opposite side of the bottom gap (3). This closes the
plate airtight with the bodies.
8. Reconnect the power cord to a wall outlet
and turn on the power.
Cleaning the housing
Switch off the device before each cleaning and
unplug the mains plug. Clean the housing of the
Airfresh Clean 400 with a slightly moistened cloth.
9. Replacing the filter
The combination filter should be replaced by a
new one after approx. 4320 operating hours.
After approximately 4320 operating hours, the
ON/OFF indicator light on the instrument's con­
trol panel flashes to indicate the recommended
filter change. Only use original Soehnle filters!
To change the filter, proceed as follows:
1. Switch off the appliance and unplug it from
the mains supply.
2. Open the unit as described in chapter 8 and
remove the Soehnle HEPA combi filter (2.4).
3. Now insert the new Soehnle HEPA combina­
tion filter into the housing. Make sure that
the new filter unit is inserted correctly.
GB
13