IO-Link process data
The probes only have „process data in" data. These are 32 bit wide and correspond to
the position of the measuring pin in nanometers, signed.
Configuration
It is not necessary to configure the probe for operation. According to IODD, a rolling
average filter can be configured starting at address 0x0040 of the ISDU. Possible
values for the averaging time are 0 to 100 ms.
Device Information
According to the IO-Link specification, a probe holds the following device information.
Key
VendorID
DeviceID
Article number (ProductID)
Product name (ProductName)
Serialnumber
Subject to change without notice. Errors and omissions excepted
Value
Assignment of the device to the manufacturer,
fixed 1055
Identification number for a type of device with
the same function. All probes have the ID 1000.
Identification of the individual product. This
number is equal to the article number / order
number
The product name (e.g. „T501FIOL")
Unique serial number (also identification num-
ber) of the measuring device
Page 15/20