3. Avoid overcurrent. When the current
exceeds the jump starter's peak current
value, stop using the jump starter. For
example, when the starting motor is stuck,
the current is very large, which will cause
damage to the jump starter.
4. Avoid overpressure. Please check the car
voltage carefully. For example, a 12V jump
starter can start a 12V car but not a 24V
diesel car.
5. Please don't start the car continuously,
between starting twice you should allow an
interval of at least 30 seconds to 1 minute.
6. Please don't charge the device immedi-
ately after starting the car to avoid damage
to the battery.
7. Please turn off unneeded appliances
before starting your car with the device, such
as car air conditioners, headlights,
high-power speakers, and devices on the
cigarette lighter. It will help start the car in an
easier way.
Smart Clamps
Smart clamps have multiple protection functions including
Short Circuit Protection, Over Discharge Protection, Reverse
Connection Protection, Reverse Charge Protection, Input Low /
High Voltage Protection, High Temperature Protection and so
on.
07
Function
Details
The red light is always on when the clamp
is short-circuited, the buzzer sounds long,
Short Circuit
and the protection can be automatically
Protection
released after the fault is removed.
If the clamps are not connected to the
correct positive and negative terminals,
Reverse
the light will turn red and the buzzer keeps
Connection
beeping for a short time. The protection
Protection
can be automatically released after
troubleshooting.
The output is automatically disconnected
Reverse
during reverse charge protection, and the
Charge
traffic lights flash alternately. The
Protection
protection can be automatically released
after the fault is removed.
If the clamps are connected to the start
Input Low /
port which is higher or lower voltage, the
High Voltage
protection function will be triggered and
Protection
the red light is always on.
The clamps will automatically be
disconnected when it is hot(≥80 ºC±10 ºC),
High
and the light will keep showing red; when
Temperature
the temperature of the clamp is lower
Protection
than 70 ºC, the protection is automatically
released.