Herunterladen Inhalt Inhalt Diese Seite drucken

Operating Procedures; Starting The Generator - Makita EG-Serie Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 50
Death, personal injury and/or property damage may
occur unless instructions are followed carefully.
Use battery of recommended capacity.
Turn the starter switch to the " 〇 " (STOP)
position when mounting or dismounting
battery. When mounting battery, connect the
positive (+) cable ¿ rst and then the negative
(-) cable to the battery. Be careful not to
short battery cables. When dismounting
battery, disconnect negative (-) cable ¿ rst.
RED CABLE
BLACK CABLE : To negative (-) terminal
Should the connection be made in incorrect
manner, the generator will be broken.
Tighten bolts and nuts on terminals securely
so they will not be loosened by vibration.
Disconnect battery cables when charging
battery.

4. OPERATING PROCEDURES

(See Fig.

1. STARTING THE GENERATOR

Check the oil level before each operations as
outlined by the article "CHECK ENGINE OIL"
(a) Turn the Engine switch to the position " ¦ " (ON).
(See Fig. -①)
❶ " ¦ " (ON)
❷ " 〇 " (OFF)
(b) Open the fuel valve. (See Fig. -②)
❶ OPEN
❷ CLOSE
(c) Set choke lever to close if the engine is cold.
(See Fig. -③)
❶ CHOKE LEVER
❷ CLOSE
❸ OPEN
Downloaded from
www.Manualslib.com
WARNING
: To positive (+) terminal
)
CAUTION
manuals search engine
(d) [Recoil starter model]
Pull the starter handle slowly until passing the
compression point (resistance will be felt), then
return the handle to its original position
and pull briskly. (See Fig. -④)
❶ PULL BRISKLY
If the engine fails to start after several attempts,
repeat above procedures with choke lever returned
to "OPEN" position.
Do not fully pull out the rope.
After starting, allow the starter handle to return to
its original position while still holding the handle.
(e) [Electric starter model]
Insert the key into the key switch and turn it
clockwise to the " ¦ " (RUN) position to start the
engine.
Then turn the key further to the "
position.
The engine will be started by starting motor.
(See Fig. -⑤)
❶ " 〇 " (STOP)
❷ " ¦ " (RUN)
❸ "
" (START)
CAUTION
Do not run the starting motor over 5 seconds
continuously.
If the engine fails to start, return the key to
the " ¦ " (RUN) position and wait about 10
seconds then start again.
Do not turn the key switch to "
position when the engine is running to
prevent damage of starting motor.
When starting the engine by recoil starter,
set the key switch at the " ¦ " (RUN) position
and pull the starter handle.
(f) After the engine started, return the choke lever
gradually to "OPEN" position.
(See Fig. -⑥)
❶ CHOKE LEVER
❷ CLOSE
❸ OPEN
(g) Warm up the engine without a load for a few
minutes.
EN
FR
DE
NL
ES
" (START)
IT
PT
GR
NO
SE
FI
DK
RU
" (START)
7

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis