Malfunction remedy
Malfunction
Pump does not run
Insufficient delivery rate
Unit switches off after a short
running period
The water pattern is uneven or
incomplete

Technical data

Unit data
Aquarius Fountain Set Eco
Rated voltage
Mains frequency
Power consumption
Protection type
Max. pump capacity
Max. water column
Max. pump immersion depth
Water feature connection
Stepped hose adapter
Dimensions
Weight
Possible cause
No mains voltage
Impeller unit blocked
Impeller unit running slug-
gishly
Filter housing clogged
Pressure loss in the hose too
high
Water temperature too high
Unit is overloaded
Nozzle is blocked
AC V
Hz
W
l/h
m
m
mm
Length
mm
Width
mm
Height
mm
kg
Remedy
Check the mains voltage.
Clean the impeller unit
Clean the impeller unit
Clean the filter housing.
 Reduce the hose length and
 Route hose in a straight line
Observe the maximum water
temperature of +35 C
 Remove blockage
 The unit will switch on
 Clean nozzle
750
1000
2000
230
230
230
50
50
50
9
11
18
IP 68
IP 68
IP 68
720
1000
2100
1.1
1.3
2.1
2
2
2
G1
G1
G1
13/19/25 13/19/25 13/19/25 13/19/25 13/19/25
205
205
205
180
180
180
140
140
140
1.8
1.8
2.0
connecting pieces to a mini-
mum
again automatically as soon
as it has cooled down.
3000
4000
230
230
50
50
26
42
IP 68
IP 68
3000
4000
2.5
2.9
2
2
G1
G1
205
205
180
180
140
140
2.2