On the Slave's configure the following:
MAX
Set the maximum charging current for the EV connected to this
Solar Box.
After setting the Slave's load balancing option, there will be an error message on
the display: "ERROR NO SERIAL COM".
This indicates, that the Slave unit was not able to communicate to the Master. This
message will disappear after the modules are correctly wired up.
See also ERROR MESSAGES below.
Hardware connections
Connect the A, B and GND connections form the Master to the Slave(s). So, A
connects to A, B goes to B etc.
If you are using the sensorbox, you should also connect the A, B and GND wires
to the same screw terminals of the Solar Box. Make sure that the +12V wire
coming from the sensorbox is connected to only one Solar Box. This wire will
provide power to the sensorbox.

ERROR MESSAGES

If an error occurs, the Solar Box will stop charging and display one of the following
messages:
ERROR NO
SERIAL COM
ERROR NO
CURRENT
ERROR
HIGH TEMP
No signal from the sensorbox or other Solar Box (when
load balancing is used) has been received for 10
seconds. Please check the wiring tot the sensorbox or
another Solar Box.
There is not enough current available to start charging,
or charging was interrupted because there was not
enough current available to keep charging. The Solar
Box will try again in 60 seconds.
The temperature inside the module has reached 65
Charging is stopped. Once the temperature has
dropped to 55
o
C charging is started again.