ALL MENU OPTIONS
You can use the left or right arrow button to switch between the settings.
Confirm your choice always with the middle button.
CONFIG: Configure Solar Box with Type 2 socket or fixed cable
o
SOCKET
o
FIXED
LOCK: Enable or disable the locking actuator (config=socket)
o
DISABLED
o
SOLENOID
o
MOTOR
MODE: Use Normal mode or Smart/Solar mode (requires Sensorbox)
o
NORMAL
o
SMART
o
SOLAR
START – to allow the charger to start up in case of insufficiently
generated solar energy, a START button can be set from -1A to -16A.
The charger will use the missing power from the grid.
STOP – with the STOP function, a time of up to 60 minutes can be
specified how long the charger will continue with the above mentioned
START function. STOP function can also be set to DISABLED. The
charger will continue to charge even if there is no solar energy at all.
LOAD BAL: Load Balancing mode for 2 – 4 Solar Box units
o
DISABLED
o
MASTER
o
SLAVE 1-3
MAINS: Set Max Mains current / I-MAX HOME (*)
10 – 99A
o
MIN: Set MIN charge current fort he EV (*)
6 – 16A
o
CIRCUIT: Set the max current the circuit can handle (load balancing)
13 – 80A
o
MAX: Set MAX charge current for the EV
o
10 – 80A
Solar Box has a type 2 socket
Solar Box has a fixed charging cable
No lock is used
Ratio lock (PRESET)
Phoenix contact lock
The EV will charge with the current set at MAX
The EV will charge with a dynamic charge current,
depending on Sensorbox data and MAINS, MAX, MIN
settings
The EV will charge on solar power only (PRESET)
No load balancing is used (PRESET)
Set one of the Solar Box units to Master
Set the rest to Slave 1 – 3, when using load balancing
ENGLISH 25
ENGLISH 25
SOLAR BOX / EV080
SOLAR BOX / EV080