14
Annex A
14.1 Technical Data
Marking
Type designation
CE marking
Explosion Protection
Global (IECEx)
Gas and dust
Europe (ATEX)
Gas and dust
Certifications and certificates
Certificates
Ship approval
Further parameters
Further information
Safety data
Max. voltage U
Max. current I
Max. power P
Max. connectable
capacitance C
IIC
IIB
Max. connectable
inductance L
o
IIC
IIB
Internal capacitance C
Internal inductance L
Safety-related
maximum voltage
202806 / 9170614310
2020-08-31·BA00·III·en·03
9170/21-30-10
C
0158
IECEx BVS 09.0041X
Ex nA nC [ia Ga] IIC T4 Gc
[Ex ia Da] IIIC
DMT 02 ATEX E 195 X
E II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
E II (1) D [Ex ia Da] IIIC
IECEx, ATEX, Brazil (ULB), EAC, India (PESO), Canada (FM),
Korea (KGS), USA (FM)
CCS, DNVGL
see respective certificate and operating instructions
9.6 V
o
10 mA
o
24 mW
o
o
3.6 μF
26 μF
350 mH
1000 mH
2.42 nF
i
negligible
i
253 V