»Status Output« sockets
»Status Output« sockets
The Status Output sockets of the central power supply help you monitor the incoming
power supply.
For this, you can use the GPIO function of compatible console or target modules (see
Config Panel 21
manual).
NOTE:
After activating the GPIO function in the configuration of a console
module or a target module, two lines of the PS/2 mouse and PS/2 keyboard inter-
face can receive signals from the outside (input) or transmit signals to the outside
(output).
To monitor the central power supply, connect a Status Output socket to a PS/2
mouse or PS/2 keyboard interface of a compatible console or target module.
Now use the console or target module to configure the two lines of this interface (
or
) as input and optionally enter an OSD message.
K2
M3/M4
Depending on whether you connected the PS/2 mouse or PS/2 keyboard interface,
the lines are monitored via contacts
Line
Status
Line 1
Enabled
(K1/M3)
Disabled
Line 2
Enabled
(K2/M4)
Disabled
6 · G&D MultiPower-2-12V
(keyboard) or
K1/K2
Meaning
The external main power supply (Main) provides the 
required voltage.
The external main power supply (Main) is switched off 
or not connected.
The external redundant power supply (Red.) provides the 
required voltage.
The external redundant power supply (Red.) is 
switched off or not connected.