Setting the work cycle
• Move dip 3 D1 to ON, led L1 will light up.
• Press S1, the motor will rotate in the closing direction.
• When it reaches the closing travel limit press S1, the motor will rotate in the opening direction.
• When it reaches the opening travel limit press S1, the motor will rotate in the closing direction.
• When it reaches the closing travel limit press S1 again, the motor will stop.
• Move dip 3 D1 to OFF to return to normal operation.
SYSTEM MANAGEMENT OPERATIONS
Attention! Before memorising the transmitters for the first time remember to cancel the entire memory
content by pressing and holding down S1 until led L1 remains lit.
• Memorizing channel codes
This operation is carried out using button S1.
• The first time S1 is pressed L1 will flash once every 2 seconds; this operation allows you to automatically
memorise the Open-Stop-Close functions in a two or four channel remote control (see fig. 4 channel
selection). Before five seconds has passed press any button on the chosen remote control transmitter,
the led will remain lit while the function is memorised and then begin to flash again.
TXQ504C2: Channel A = OPEN - Channel B = CLOSE
TXQ504C4: Channel A = OPEN - Channel B = CLOSE - Channel C = STOP
- after 5 seconds of inactivity the procedure will quit and led L1 will switch off.