Herunterladen Inhalt Inhalt Diese Seite drucken

Motor Connection - Cardin Elettronica S504 Serie Inbetriebnahme Und Benutzung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 29

Motor connection

• Connect one of the motor phases to binding post 3 - F1; the neutral wire to binding post
4 - C; and the second motor phase to binding post 5 - F2.
• Connect the 230V power supply to binding posts 1 and 2.
• If the motor rotates in the wrong direction, invert the F1 and F2 phase wires.
Selector switch connection
• Wire a selector switch or an open close button between binding posts 7 - 8
- 9 and select the required function using dip-switch D1 as follows:
Function selection dip-switches for binding posts 7, 8 and 9
dip 1
dip 2
OFF
OFF
ON
OFF Sequential button
OFF
ON
ON
ON
T1
T2
Open
Close
Timer
Open
Close
Open
Close
Default option
Sequential button = open - stop - close - stop
Dead man function only during closing
Dead man function during opening and closing
15
Dip D1
Note

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

S508 serie504 t10508 t10

Inhaltsverzeichnis