VENESSE | VCV
BASIC FEATURES
– Length 2.5 m
– Air flow up to
00 m
/h (ISO 27 327-1)
3
– The construction of the adjustable exhaust lamellas ensures
a high output
– The insulated shell means completely silent curtain operation,
even at full output
– Easy installation
– AirGENIO control (CO,SU)
– Standard colour RAL 9016 (any RAL – based colours may be
provided on customer's request)
The VENESSE is a vertical air curtain for right and left installation
for use in representative premises, such as
restaurants and shopping centres with a recommended
width up to 4 m.
The VENESSE is for use in dry indoor environments with
an ambient temperature of +5 °C to +35 °C, and relative
humidity up to 80 %. It is suitable for moving air that is free
of large dust particles, grease, chemical vapours and other
impurities. The air curtain has IP 20 electrical protection. The
air curtain's installation must always be planned by a heating
and cooling technician.
152
GRUNDEIGENSCHAFTEN
– Ausführungen in der Länge 2,5 m
– Luftleistung bis zu 4700 m
– Die Konstruktion der einstellbaren Ausblaslamellen sichern
eine höhere Luftleistung
– Sehr leiser Betrieb des Luftschleiers auch bei voller Leistung
dank des isolierten Gehäuses
– Einfache Installation
– AirGENIO Steuerung (CO,SU)
– Farbe im Standard RAL 9016 (Farbliche Ausführung des
Luftschleiers je nach Kundenwunsch)
VENESSE ist ein vertikaler Luftschleier in universellem Design
an s offices
für den Rechts- oder Linkseibau mit Anwendung in Repräsen-
tationsräumen, wie in Banken, Bürogebäude, Gaststätten
und Einkaufszentren mit empfohlener Öffnungsbreite bis
zu 4 Metern.
Der Luftschleier VENESSE Comfort ist für den Betrieb in tro-
ckenen Innenräumen mit einer Umgebungstemperatur von +5
°C bis +35 °C und einer relativen Luftfeuchtigkeit bis 80 %
vorgesehen. Er ist für die Luftbeförderung ohne groben Staub,
Fettgehalt, Chemikaliendunst und weiterer Verunreinigungen
geeignet. Der Luftschleier hat die Schutzklasse IP 20. Die In-
stallation eines Luftschleiers muss immer ein Lufttechnik- und
Heizungsplaner planen und vorgeben.
AIR CURTAINS
LUFTSCHLEIER
air-only /
ohne Heizung
water heater /
Wasserwärmetauscher
electric wire heater /
Elektroheizung
/h (ISO 27 327-1)
3

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für 2VV VENESSE VCV-B-25S

  • Seite 1 VENESSE | VCV AIR CURTAINS LUFTSCHLEIER air-only / ohne Heizung water heater / Wasserwärmetauscher electric wire heater / Elektroheizung BASIC FEATURES GRUNDEIGENSCHAFTEN – Length 2.5 m – Ausführungen in der Länge 2,5 m – Air flow up to 00 m /h (ISO 27 327-1) –...
  • Seite 2 VENESSE | VCV AIR CURTAINS LUFTSCHLEIER PRIMARY PARAMETERS WICHTIGSTE PARAMETER Air curtains with an electric heater unit are equipped with an Luftschleier mit elektrischem Erhitzer verfügen über einen auf operational thermometer with automatic reset for temperatures +50°C eingestellten Betriebsthermostat mit automatischem above 50°C and an emergency thermometer with manual reset, Reset sowie über einen Notthermostat mit manuellem Reset, which turns the entire device off if the temperature inside the...
  • Seite 3: Installation And Assembly

    VENESSE | VCV AIR CURTAINS LUFTSCHLEIER ecommended mi ing points for -way valve Empfohlen f r den Wasserventil des Wasserw rmetauschers -Wege- entil 0 °C 0 60 °C 0 50 °C 0 °C Control Steuerung -way valve -Wege- entil ZV2-230-08,0-20 ZV2-230-08,0-20 ZV2-230-08,0-20 ZV2-230-08,0-20...
  • Seite 4 VENESSE | VCV AIR CURTAINS LUFTSCHLEIER Minimum distance from solid construction Mindestabstand von einer Baukonstruktion Door opening Türöffnung Min. 200 mm service hood Servicedeckel Door opening Türöffnung Min. 200 mm CONTROL STEUERUNG The VENESSE air curtains are produced with COMFORT or Der VENESSE Luftschleier werden mit COMFORT- oder SUPERIOR controls (CO and SU).
  • Seite 5 VENESSE | VCV AIR CURTAINS LUFTSCHLEIER CONTROL STEUERUNG verview of functions and sensor connections ersicht der un tionen und ensoranschl sse COMFORT SUPERIOR Air E control VCS-R3-CO VCS-R3-SU Type of controller Touch screen Touch screen Steuerungstyp Touch-screen Touch-screen Mode Manual / Auto Manual / Auto Modus Manuell / Automatisch...
  • Seite 6 VENESSE | VCV AIR CURTAINS LUFTSCHLEIER CHAINING EXAMPLE COMFORT / SUPERIOR COMFORT / SUPERIOR lo al oor contact function active lo al oor contact function not active ordere- r onta t ist a tiv ordere- r onta t ist nicht a tiv / Oder / Oder THERMO 80...
  • Seite 7 VENESSE | VCV AIR CURTAINS LUFTSCHLEIER ACCESSORIES ZUBEHÖR More details can be found on the relevant page in Weitere Details finden Sie auf der entsprechenden this catalog Seite in diesem Katalog REQUIRED ACCESSORIES ERFORDERLICHES ZUBEHÖR For air curtain with water heater only. Nur für Luftschleier mit Wasserwärmetauscher -way or -way valve with servo drive -Wege- oder -Wege- entil mit ervoantrie...
  • Seite 8: Wiring Diagrams

    VENESSE | VCV AIR CURTAINS LUFTSCHLEIER WIRING DIAGRAMS ELEKTRISCHE SCHALTPLÄNE All connection schematics shown in the catalogue are for Sämtliche im Katalog aufgeführten Schaltpläne sind nur in- information only. When assembling the product, follow only formativ. Bei der Montage des Produkts richten Sie sich bitte the values, instructions and schematics shown on the product ausschließlich nach den Werten auf dem Typenschild, nach den itself or delivered with the product.
  • Seite 9 VENESSE | VCV AIR CURTAINS LUFTSCHLEIER WIRING DIAGRAMS SCHALTPLÄNE C - - 5- -CS... C - - 5- -CS... C - - 5- -CS... open AirGENIO COMFORT Signal to SLAVE unit External control - ON/OFF Room thermostat (input) DOOR contact (input) Signal from MASTER unit Signal zur SLAVE Anlage Externe Steuerung - AN/AUS...
  • Seite 10 VENESSE | VCV AIR CURTAINS LUFTSCHLEIER WIRING DIAGRAMS SCHALTPLÄNE C - - 5- -SU... C - - 5- -SU... 0-10V AirGENIO SUPERIOR HEAT MASTER 0-10V MODBUS TCP, BACnet, LAN OUTPUT OUTPUT INCENDIE ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF MODBUS RTU 13 14 11 12 72 71 75 72 71...
  • Seite 11 VENESSE | VCV AIR CURTAINS LUFTSCHLEIER WIRING DIAGRAMS SCHALTPLÄNE C - - 5- -SS... C - - 5- -SS... 0-10V AirGENIO SUPERIOR HEAT 0-10V LPHW out sensor (included in delivery) Signal to SLAVE unit Antifreeze thermostat (NC) External control - ON/OFF Room thermostat (input) DOOR contact (input) Signal from MASTER unit...
  • Seite 12 CODIERSCHLÜSSEL C -B-25 E-CO-0-2 C -B-25 E-CO-0-2 2 – 2VV-Version 2 – 2VV version 0 – White colour RAL 9016 (standart) 0 – Weiße Farbe RAL 9016 9 – RAL Farbe je nach Wunsch 9 – Other colours according to RAL N –...

Inhaltsverzeichnis