TROUBLESHOOTING

Fault cause
Gas smell
Leaking LPG is extremely
flammable.
Can cause explosions.
No gas flow.
Still no gas flow

MAINTENANCE

Upon proper ASSEMBLY and OPERATION, the product is maintenance-free.

REPLACEMENT

If there is any sign of wear or if the product or parts thereof are damaged, it must be replaced.
When the product has been replaced, observe the steps ASSEMBLY, LEAK TESTING and
START-UP. To ensure that the installation works faultlessly under normal operating
conditions, it is recommended that you replace the device within 10 years of the date of
manufacture.
In commercial applications, according to DGUV regulation 79, parts of consumer
units that are subject to wear and ageing* must be replaced after 8 years. This does
not apply if the proper condition has been confirmed by an expert.
* System parts that are subject to wear or ageing are, for example, membranes,
automatic and manual changeover valves, pressure regulators, hoses assemblies.
The gasket in the inlet connector (if provided) must be changed every time the cylinder has
been replaced or disassembled. It must also be replaced if it is damaged or the connection is
no longer tight.

RESTORATION

If the actions described in TROUBLESHOOTING do not lead to a proper restart and if there is
no dimensioning problem, the product must be sent to the manufacturer to be checked. Our
warranty does not apply in cases of unauthorised interference.

SHUT-DOWN

Close the gas supply and then the shut-off fittings of the connected loads. When the LPG
system is not in use, all valves must remain closed.
Close all free connections in the feed lines of the LPG system tightly with a suitable cap to
prevent gas from flowing out.

DISPOSAL

To protect the environment, our products may not be disposed of along with
household waste.
The product must be disposed of via a local collection station or a recycling station.
Artikel-Nr. 02 491 50 e
Action
 Close the gas supply.
 Do not use any electric switches.
 Do not use a phone in the building.
 Ventilate rooms well.
 Shut down the LPG system.
 Contact a specialised company.
 open the gas cylinder valve or the shut-off fittings.
 pressure regulator is damaged, replace it.
 see TROUBLESHOOTING in the operating manual that
was supplied with the product