0 Hardware Short Circuit Protection
When battery detects a short circuit in charge (discharge) fault, the charge (discharge) MOSFET is
turned OFF. When the battery identifies the short-circuit in charge (discharge) condition, dischar-
ge MOSFET is re-enabled. When the pack is removed and re-inserted, the short circuit condition
is cleared.
When the recovery condition for a charging fault is detected, the CHG MOSFET is allowed to be
turned ON if other safety and configuration states permit.
When the recovery condition for a discharging fault is detected, the DSG MOSFET
is allowed to be turned ON if other safety and configuration states permit