Herunterladen Diese Seite drucken

VOLTCRAFT PS-200 Bedienungsanleitung Seite 2

Taschenwaage

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operating Instructions
Pocket Scale
PS-200
Item No. 1782519
Intended Use
This product is designed to weigh objects with a max. weight of 200g. Power is supplied via 2 AAA batteries.
The product is not intended for medicinal or commercial use. It is intended for indoor use only. Do not use it
outdoors. Contact with moisture, e.g. in bathrooms, must be avoided under all circumstances.
For safety and approval purposes, you must not rebuild and/or modify this product. If you use the product for
purposes other than those described above, the product may be damaged. Read the instructions carefully
and store them in a safe place. Make this product available to third parties only together with its operating
instructions.
This product complies with the statutory national and European requirements. All company names and
product names are trademarks of their respective owners. All rights reserved.
Delivery Content
• Scale
• Cover
Up-to-date Operating Instructions
Download the latest operating instructions at www.conrad.com/downloads or scan the
QR code shown. Follow the instructions on the website.
Explanation of Symbols
The symbol with the exclamation mark in the triangle is used to indicate important information in
these operating instructions. Always read this information carefully.
The arrow symbol indicates special information and advice on operation.
Safety Instructions
Read the operating instructions carefully and
especially observe the safety information. If
you do not follow the safety instructions and
information on proper handling in this manual,
we assume no liability for any resulting personal
injury or damage to property. Such cases will
invalidate the warranty/guarantee.
a) General Information
• The product is not a toy. Keep it out of the reach of
children and pets.
• Do not leave packaging material lying around
carelessly. This may become dangerous playing
material for children.
• Protect the product from extreme temperatures,
direct sunlight, strong jolts, high humidity,
moisture, flammable gases, steam and solvents.
• Do not place the product under any mechanical
stress.
• If it is no longer possible to operate the product
safely, take it out of operation and protect it from
any accidental use. Safe operation can no longer
be guaranteed if the product:
- is visibly damaged,
- is no longer working properly,
- has been stored for extended periods in poor
ambient conditions or
- has
been
subjected
to
any
transport-related stresses.
• Please handle the product carefully. Jolts, impacts
Operating Elements
3
1
2
4 5 6
7
• 2x 1.5 V batteries (type AAA)
• Operating instructions
or a fall from a low height can damage the product.
• Maintenance, modifications and repairs must only
be completed by a technician or an authorised
repair centre.
• If you have questions which remain unanswered by
these operating instructions, contact our technical
support service or other technical personnel.
• Operation
in
environments
electromagnetic fields may result in incorrect
displayed values.
• Do not leave objects you wish to weigh on the
scale for too long and do not overload the scale.
The measuring element could be damaged.
b) Batteries
• Correct polarity must be observed while inserting
the battery.
• The batteries should be removed from the product
if it is not used for a long period of time to avoid
damage through leaking. Leaking or damaged
batteries might cause acid burns when in contact
with skin, therefore use suitable protective gloves
to handle corrupted batteries.
• Batteries must be kept out of reach of children. Do
not leave batteries lying around, as there is risk,
that children or pets swallow them.
• All batteries should be replaced at the same time.
Mixing old and new batteries in the product can
serious
lead to battery leakage and product damage.
• Batteries must not be dismantled, short-circuited or
thrown into fire. Never recharge non-rechargeable
batteries. There is a risk of explosion!
1
LCD display
2
Weighing platform
3
Protective cover
4
ON/OFF
5
MODE
6
TARE
8
7
PCS
8
Battery compartment cover
Operation
a) Inserting / replacing batteries
• Remove the battery compartment cover (8).
• Insert 2x AAA batteries, matching polarity as
shown inside the battery compartment.
• Replace the battery compartment cover (8).
Replace the batteries when "LO"
appears on the LCD display (1).
b) Weighing
• Place the scale on a stable, horizontal and even
surface.
• Carefully slide the protective cover (3) off. Close
after use
• Touch ON/OFF (4) to turn the scale on, and wait
until "0.00" is shown. If another value appears
Touch TARE (6).
• Touch MODE (5) to toggle through units of
measurement
(g, oz, ozt, dwt, ct,
• Place the object you wish to weigh on the weighing
platform (2). If the weight exceeds the weighing
range, the LCD display (1) will show "O". If this
happens remove the object from the weighing
surface immediately.
• Touch ON/OFF (4) to turn the scale off.
The scale turns off automatically after
approximately 2 minutes of inactivity.
c) Tare Function
The weighing capacity includes the
weighing container. It is recommended
to use a weighing container which is as
light as possible.
The tare function is used to measure net weight when
using a container. The tare function factors in the
weight of the container so the scale only measures
the net weight of the object you wish to weigh.
• Touch ON/OFF (4) to turn the scale on, then place
an empty measuring container (bowl, basket, etc.)
on the weighing platform (2). Wait until the LCD
display (1) stabilizes.
• Touch TARE (6). The display will show the value
"0.00" including the measuring container.
with
strong
• Place the object you wish to weigh in the
measuring container. The displayed weight will be
the net weight of the object you are weighing.
• To continue weighing without the measuring
container, remove the container from the weighing
surface and Touch TARE (6).
d) Counting Function
This function determines the quantity of units of an
equal weight.
• Touch ON/OFF (4) to turn the scale on.
• Place (25, 50, 75 or 100) objects on the weighing
platform (2).
• Touch and hold PCS (7) until the number "25"
appears on the LCD display.
• Touch MODE (5) to set a reference unit number
(25, 50, 75 or 100).
• Touch PCS (7). The LCD display (1) will show the
number of units.
• Add or remove objects from the weighing platform
(2).
• Touch MODE (5) to return to normal weighing
mode.
The reference value will be stored until
you set a new value.
e) Calibration
The scale has been calibrated at
the factory. If accuracy fails, first try
replacing the batteries.
A standard test weight of
included) is required for calibration.
The weighing platform (2) must be empty.
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights
including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication
represents the technical status at the time of printing.
Copyright 2019 by Conrad Electronic SE.
• Touch ON/OFF (4) to turn the scale on.
• Touch and hold MODE (5) until the LCD display
(1) shows "CAL".
• Touch MODE (5) again. "CAL" will flash on the
LCD display (1), followed by "200g" which is the
weight you need to put on the weighing platform
(2).
• Place the calibration weight on the weighing
platform (2). Calibration is completed when
"PASS" appears on the LCD display (1).
• If a calibration error has occurred, "FAIL" will
show on the LCD display (1). Please repeat the
calibration process.
• Remove the calibration weight from the weighing
platform (2) and turn off the scale.
Care and Cleaning
• The product is maintenance-free except for
potential battery replacement and occasional
cleaning.
gn).
• Do not use any aggressive cleaning agents,
rubbing alcohol or other chemical solutions as
they can cause damage to the housing and
malfunctioning.
• Clean the product with a dry, fibre-free cloth.
Disposal
a) Product
Electronic
waste and must not be disposed of in
the household waste. At the end of its
service life, dispose of the product in
accordance with applicable regulatory
guidelines.
Remove any inserted batteries and
dispose of them separately from the
product.
b) Batteries
You as the end user are required by
law (Battery Ordinance) to return all
used batteries. Disposing of them in the
household waste is prohibited.
Contaminated batteries are labeled with
this symbol to indicate that disposal in
the domestic waste is forbidden. The
designations for the heavy metals
involved are: Cd = Cadmium, Hg =
Mercury, Pb = Lead (name on batteries,
e.g. below the trash icon on the left).
Used batteries can be returned to collection points
in your municipality, our stores or wherever batteries
are sold.
You thus fulfill your statutory obligations and
contribute to the protection of the environment.
Technical Data
Power supply .......................2 x AAA battery
Battery life ............................Up to 6 months
Operating current .................1.52 mA
Weighing range ...................0.05 –
Resolution ............................0.01 g
Accuracy ..............................± 0.03 g
Auto shut-off ........................2 mins
Measuring units ...................g, oz, ozt, dwt, ct, gn
Operating conditions ............ 5 to +40 ºC, 0 – 70%
Storage conditions ............... -10 to +60 ºC, 0 – 85%
LCD (W x H) ........................48 x 30 mm
Weighing platform (W x H) ..57 x 70 mm
Dimensions (L x W x H) .......125 x 68 x 18 mm
Weight .................................116 g (without batteries)
200g
(not
*1782519_v4_01319_02_dh_m_en
devices
are
recyclable
200 g
RH (non-condensing)
RH (non-condensing)

Werbung

loading

Diese Anleitung auch für:

1782519