Twist both ends of the exhaust hose into the square fixing clip and the
flat fixing clip.
Insert the square fixing clip into openings at back of the air conditioner.
Put the other end of the exhaust hose to the near windowsill.
WINDOW SLIDER KIT INSTALLATION
The installation manner of window slider kit is mostly in "horizontal" and
"vertical", No much difference in actual process.
Internal Tank Water Full Alarm Function
The inner water tank in the air-conditioner has one water level safety
switches, it controls water level. When water level reaches an anticipated
height, the water full indicator lamp lights up. (If water pump is damaged,
when the water is full, please remove the rubber blockage at the bottom
of unit, and all water will drain outside.)
CLEANING MAINTENANCE
Before cleaning, be sure to disconnect the unit from any electric supply
outlet.
First clean the surface with a neutral detergent and wet cloth, and then
wipe it with a dry cloth.
Do not use gasoline or other chemicals to clean the unit.
Do not wash the unit directly.
If the conditioner is damaged, please contact the dealer or repair shop.
Air Filter
If the air filter becomes clogged with dust/dirt, the air filter should be
cleaned once every two weeks.
Open the air inlet grille and take off air filter.
Clean the air filter with neural detergent in lukewarm (40°C) and dry it
up in the shade.
Putting the air filter into the inlet grille, replace the components as
they were.
TROUBLE SHOOTING
Troubles
Possible Causes
The unit
• Water full indicator lamp blinks, and
does not
water tank is full.
start when
• Room temperature is higher than
pressing on/
the setting temperature. (Electric
off button
heating mode)
• Room temperature is lower than
the setting temperature. (Cooling
mode)
The unit
• The doors or windows are not closed.
doesn't cool
• There are heat sources inside the
enough
room.
• Exhaust air hose is not connected
or blocked.
• Temperature setting is too high.
• Air inlet is blocked.
Auto Power-
Heating protection, when the temper-
Off in heat-
ature at the air outlet exceeds 70
ing mode
the unit will power off automatically.
Noisy
• The ground is not level or not flat
enough
• The sound comes from the flowing
of the refrigerant inside the air
conditioner
Air conditioner
EN
Suggested Remedies
• Dump the water out
of the water tank.
• Reset the temperature
• Reset the temperature
• Make sure all the
windows and doors
are closed.
• Remove the heat
sources if possible
• Connect or clean the
exhaust air hose.
• Reset the temperature
• Clean the air inlet.
Restart the unit at
C,
enough lower room
o
temperature.
• Place the unit on a
flat, level ground if
possible
• It is normal.
7