Installation
• Connect the touchscreen with the RJ45 port 1, 2 or 3 of the connected controller. Use a twisted pair cable (preferably
a shielded FTP or STP). Both the touchscreen 2 and the connected controller are equipped with a RJ45 port. Therefore
the RJ45 connectors must be attached to the cable to connect the connected controller on the one side and the
touchscreen 2 on the other.
• The touchscreen 2 can be supplied with power using Power over Ethernet (PoE) via the same twisted pair cable, for
which you use the Niko PoE power supply (550-00501). Alternatively, you can provide a separate power supply cable,
which you connect to a separate 24 Vdc power supply module in the electrical cabinet. In that case, you will need a 24
V power supply cable such as an SVV, JYSTY, TPVF or UTP cable in addition to the twisted pair cable.
Wiring diagrams
With Power over Ethernet (PoE)
* twisted pair cable (UTP, FTP of STP)
550-00501
L
N
49
Touchscreen 2