Connection

NOTICE
Material damage caused by ingress
of humidity.
Damage or destruction of the device.
X Use a plug-in connection that guar-
antees at least the same degree of
protection as the device.
NOTICE
Material damage caused by improper
installation.
Damage or destruction of the device.
X Do not twist the plug and the
socket against each other.
X Tighten the union nut of the plug-in
connection to the defined torque.
The device has two connections:
Input: Plug M12-A-5 type A, see Tab. 3
ƒ
Output: Socket M12-A-5 type E, see
ƒ
Tab. 4
26
4.1
Connecting the device to the
supply voltage
NOTICE
Material damage caused by wrong
mains voltage.
Damage or destruction of the device.
X Connection by a skilled electrician
only.
X Operate the luminaire at safety
extra low voltage (SELV) only.
X Observe the pin assignment and
the socket assignment.
X Use a connecting cable with
strands which have a conductor
cross-section of 1.0 mm².
X Make sure that the maximum per-
missible short-circuit current of the
voltage source is not exceeded:
I
< 4 A
K
X USA and Canada: This device
must be connected to a power
supply unit of class 2.
To connect the device, we recommend
using connecting cables found in the
Waldmann range of accessories.