Panic alarm — Press buttons 1 and 3 at the same time (if the function is activated).
Check control unit state — In normal operating mode, press button
Red LED on: the system is in Total Armed state.
Red LED blinking: the system is in Partial Armed state.
Red LED on: the system is in Disarmed state.
B
l
u
e
L
E
B
l
u
e
L
E
No reply sent to control unit within 4 seconds.
Incorrect code.
Request to pass to Partial Armed state when the Total Armed state.
Forced arming request.
H
o
w
t
o
c
h
a
n
g
e
t
h
e
H
o
w
t
o
c
h
a
n
g
e
t
h
e
I.
Set the Tamper alarm to Total on the control unit or activate Test mode as described above.
II.
Remove the remote keypad by loosening the closing screw.
III.
Extract the flat battery and press any button to discharge the device completely before inserting the new battery in the
housing with the side free from markings (negative) facing downwards.
IV.
Refit the remote keypad by tightening the closing screw.
V.
Restore normal operation on the control unit.
F
a
u
l
t
s
F
a
u
l
t
s
IN NORMAL OPERATING MODE:
a)
When there is a fault in the system, the blue state LED and the amber fault LED will blink four times and the keypad
will beep three times to indicate the fault when the system is armed.
The user may force activation by running the activation procedure again.
b)
When the keypad is used to deactivate the system, the blue keypad state LED will light up and the keypad will
generate two short beeps to indicate normal operation. In presence of a fault, the keypad will beep five times and the
blue system state LED and amber fault LED will light up for 5 seconds.
c)
If the system is already being armed by a control unit, partial arming using the remote keypad is NOT possible. The
blue system state LED will blink four times to indicate a transmission error.
d)
If an incorrect code is entered four times to enter Test mode, the keypad will be deactivated for 4 minutes, all LEDs
will blink 3 times and the keypad will beep 6 times. After 1 minute, the keypad will generate a long beep to indicate
that operation was restored.
A
A
p
p
p
p
e
e
n
n
d
d
i
i
x
x
The remote keypad can be reset with the default values and restarted if the keypad code is forgotten or the remote keypad
displays a problem.

Restoring default settings:

Step 1 Remove the battery.
Step 2 Hold button 3 pressed and insert the battery.
Step 3 Hold button 3 pressed until the keypad beeps 3 times.
Step 4 Release button 3: the reset procedure is done.
<
N
O
T
E
>
:
<
N
O
T
E
>
:
The keypad code returns to the default setting 0000 after resetting.
T
e
c
h
n
i
c
a
l
s
p
e
c
i
f
i
c
T
e
c
h
n
i
c
a
l
s
p
e
c
i
f
i
c
Power supply: 1 lithium battery EL 123AP
Battery life: 5 years (typical value, may vary according to use)
Two-way radio frequency: 868.6375 MHz
Working temperature range -10°C to +45°C
Dimensions: 80 mm x 116 mm x 20.5 mm
Weight: 100g
Certification EN 50131 Grade 2, Class Ⅱ
Hereby, URMET S.p.A. declares that the radio equipment type: LED REMOTE KEYPAD KP600 is in compliance with Directive
2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.elkron.com
9
D
b
l
i
n
k
i
n
g : error for the following reasons:
D
b
l
i
n
k
i
n
g
b
a
t
t
e
r
y
b
a
t
t
e
r
y
a
t
i
o
n
s
a
t
i
o
n
s

SIMPLIFIED EU DECLARATION OF CONFORMITY

.
DS80KP55-001C

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für Elkron KP600

Inhaltsverzeichnis