("Craterfiller" current) set with "Crater Current" parameter
in the time set in "Slope time" and is maintained until the
torch button is released. Welding stops when the button is
released.
To choose the welding start mode 2T, 4T or 3L select one
of the three modes by means of the knob B and press the
knob B. After confirming the selection made, to return to
the previous page (PROCESS PARAMETERS) press the
knob B. If you want to go back to the main menu, press the
knob B again for at least 2 sec.
Spot and pause time (Spot).
If we select the spot ON time, the Spot Time function
appears on the display screen. If we select this, we can
adjust it from 0.3 to 25 seconds by means of the knob C.
Besides this function, the display screen also shows
Pause Time. If we select this, by means of the knob C, we
can regulate the pause time between one welding point or
section and another. The pause time varies between 0
(AUTO) and 5 seconds.
To access the Spot Time and Pause Time functions,
press the knob B.
Adjustment is made by turning the knob C. After confirming
the selection made, to return to the previous page
(PROCESS PARAMETERS) press the knob B. If you want
to go back to the main menu, press the knob B again for at
least 2 sec.
HSA Automatic Hot Start
Display A shows the message OFF = Off.
Pressing the knob B, the display A shows the option ON-
OFF.
To activate the function select ON=Active with the knob B.
After confirming the selection made, to return to the
previous page (PROCESS PARAMETERS) press the knob
B. If you want to go back to the main menu, press the knob
B again for at least 2 sec.
If this function is activated, the following messages appear
in sequence:
-
START CURR
Adjustment range (10-200%) of the wire speed
corresponding to the welding current, it is set using
knob C.
-
S.C. TIME
This is the duration, expressed in seconds, of the set
start current. It is set using knob C. Adjustment range
0.1-10 sec.
-
SLOPE TIME
Adjustment range 0.1-10 sec. Defines the interface
time between the first current (START CURR) and the
welding current set using knob B in the welding
programs. It is set using knob C.
CRA Crater Current
Display A shows the message OFF = Off. Pressing the
knob B, the display A shows the option ON-OFF.
To activate the function select ON=Active with the knob C.
After confirming the selection made, to return to the
previous page (PROCESS PARAMETERS) press the knob
B. If you want to go back to the main menu, press the knob
B again for at least 2 sec.
If this function is activated, the following messages appear
in sequence:
-
SLOPE TIME
Adjustment range 0.1-10 sec. It is set using knob C. It
defines the interface time between the welding current
and the crater current set using knob B in the welding
programs.
-
CRATER CURR
Adjustment range (10-200%) of the wire speed
corresponding to the welding current set using knob B
in the welding programs. It is set using knob C.
-
C.C. TIME
This is the duration, expressed in seconds, of the
previously set Crater current. It is set using knob C.
Adjustment range 0.1–10 sec.
Inductance
Adjustment can vary from -9.9 to +9.9. Factory setting is
zero. If the figure is negative, the impedance drops and the
arc becomes harder, while if it increases, the arc is softer.
To access this function, simply highlight it using the knob B
and change the value by turning the knob C. After
confirming the selection made, to return to the previous
page (PROCESS PARAMETERS) press the knob B. If you
want to go back to the main menu, press the knob B again
for at least 2 sec.
AUTO burnback
The adjustment can vary from -9.9 to +9.9. Its purpose is
to adjust the length of the wire coming out of the gas
nozzle after welding. A positive figure corresponds to
greater wire burning. Default is Auto.
To access this function, simply highlight it using the knob B
and change the value by turning the knob C. After
confirming the selection made, to return to the previous
page (PROCESS PARAMETERS) press the knob B. If you
want to go back to the main menu, press the knob B again
for at least 2 sec.
Soft Start
Adjustment can vary from 0 to 100%. This is the wire
speed expressed in percentage of the speed set for
welding, before the wire touches the piece to be welded.
This adjustment is important to obtain always good starts.
Default is 0% (AUTO).
To access this function, simply highlight it using the knob B
and change the value by turning the knob C. After
confirming the selection made, to return to the previous
page (PROCESS PARAMETERS) press the knob B. If you
want to go back to the main menu, press the knob B again
for at least 2 sec.
Pre Gas
The adjustment can vary from 0 to 10 seconds.
To access this function, simply highlight it using the knob B
and change value by turning the knob C. After confirming
the selection made, to return to the previous page
(PROCESS PARAMETERS) press the knob B. If you want
to go back to the main menu, press the knob B again for at
least 2 sec.
Post Gas
The adjustment can vary from 0 to 25 seconds.
To access this function, simply highlight it using the knob B
and change the value by turning the knob C. After
confirming the selection made, to return to the previous
page (PROCESS PARAMETERS) press the knob B. If you
want to go back to the main menu, press the knob B again
for at least 2 sec.
Options LOCK (DOUBLE LEVEL)
To access this function, simply highlight it using the knob B
and press it. The display screen A will show 16 empty text
boxes.
To unlock it, instead of the zeros, an alphanumeric code
must be entered. This must be requested from your dealer.
Once the code has been obtained, simply enter it in place
of the zeros: each letter or figure entered must be
confirmed by pressing the knob C. After entering the code,
by pressing the knob B this option is unlocked. After
confirming the selection made, to return to the previous
page (PROCESS PARAMETERS) press the knob B. If you
want to go back to the main menu, press the knob B again
for at least 2 sec.
Double Level (optional)
This type of welding makes the current intensity vary
between two levels. Before setting the double level
welding, make a short weld seam to determine the wire
speed and, consequently, the current required to obtain
optimal penetration and width of the seam for the joint to
be made. In this way, it is possible to determine the wire
9

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis